GB
IE

Troubleshooting

Faults
Pump does not start
Pumps has no dis-
charge
Pump does not switch
off
Flow rate insufficient
Pump switches off after
a short period

Replacement parts/Accessories

You can order replacement parts and accessories directly via our Service Centre (see
page 13). Ensure that you include the order number when placing the order.
Item
4
9/10
11
14
Causes
Mains voltage is not applied
Float switch (
switch
Buckled pressure hose
Trapped air in the pump cas-
ing
Float switch (
drop
Reduces pump performance,
through severely contami-
nated water and additions in
the water which produce a
grinding effect
Motor contactor disconnects
the pumps because of water
pollution that is too severe.
Water temperature too high,
motor contactor breaks
Description
Floor plate + screw set (
Connector set (reducer, sealing ring, angle adapter)
8m nylon cord
Remedies
Check mains voltage
Bring float switch into higher
7) does not
position
Repair point at which the line
is bent
Tip the pump underwater until
the air escapes
Set up pumps correctly on the
7) cannot
pit base
Clean pumps and replace
wear parts
Pull out power plug and clean
the pump as well as shaft
Note maximum water tem-
perature of 35 °C!
4a)
Product No.
91100892
91100893
91100894