GENERAL INFORMATION

Scope of Delivery
Immediately upon receipt of the delivery, ensure that there
is no damage to its contents and that the type and scope
of the delivery corresponds to the delivery note and the
packing list. Please inform us immediately of any discrepan-
cies.
Germany
Contact address:
Bürkert Fluid Control Systems
Sales Centre
Chr.-Bürkert-Str. 13-17
D-74653 Ingelfingen
Tel. : 07940 - 10 111
Fax: 07940 - 10 448
E-mail: info@de.buerkert.com
International
For contact addresses, please see the last pages of these
operating instructions.
Also on the Internet at:
www.buerkert.com
Bürkert
8
GB

STRUCTURE AND FUNCTION

The direct action proportional valve can be used as an
actuator for process control, and is suitable for technical
vacuum. Low hysteresis, high reproducibility and good
response sensitivity ensure good adjustment characteris-
tics. Thanks to an elastomer seat seal, the valve is tightly
sealed (except for steam designs, etc.). Control is via the
separately available control electronics Type 1094 or Type
8605, which convert an analogue input signal into a PWM-
signal
1)
.
1)
PWM Pulse Width Modulation
Other functions of controllers Type 1094 and Type 8605
Compensation for magnetic coil heating through internal
current control
Easy adaptation of the minimum and maximum current
(start of opening and fully open) to the actual pressure
conditions
ramp function for dampinging sudden changes in the input
signal,
Type 1094: Monitor function with LED display as adjustment
aid or for external display (the monitor signal is proportional
to the coil current).
10
GB
Company
Locations
Warranty conditions
This document contains no guarantee statements. Please
refer to our general terms and conditions. The warranty shall
be valid only if the proportional valve is used in compliance
with the specifi ed conditions of use.
Information on the Internet
Operating instructions and data sheets on the proportional
valves are available on the Internet at:
www.buerkert.com

technical data

XXXX
TECHNICAL DATA
CAUTION!
Function failure if operated outside of the permissible
temperature range!
Do not use the device in outdoor locations,
Avoid heat sources that could result in temperatures higher
than the permissible temperature range.
Conformity
CE mark
EMC Directive 89/336/EEC
Low Voltage Directive
73/23/EEC
Pressure Equipment Directive
97/23/EC
Technical Data - Valve
Ambient temperature
0 to +55 °C
Fluid temperature
-10 to +90 °C
Media
neutral gases, liquids;
technical vacuum
Protection category
of valve
IP65 acc. to DIN EN 60529
data sheets
type
GB
9