Type plate
26
Holder for crevice nozzle
27
Suction pipe holder
28
Mains cable
29
Push handle fastening screw
30
Filter dedusting
31
Flat fold filter
32
Lock latch of the filter cover
33
Colour coding
● Control elements for the cleaning process are yel-
low.
● Control elements for maintenance and servicing are
light grey.

Symbols on the device

Flat fold filter, safety filter bag
Flat fold filter
Order number
Safety filter bag
Order number
Asbestos marking
CAUTION CONTAINS ASBESTOS.
Health risk posed by inhalation of fine as-
bestos dust. Observe safety regulations.

Preparation

1. Unpack the device and install the accessories.
Illustration B

Initial startup

If necessary, remove the sticker in the relevant national
language from the enclosed sheet of stickers and stick
it onto the device over the German text.
The device has 2 operating modes:
1
Industrial vacuum cleaner operation (power socket
not used)
2
Dust removal operation (power socket used)
WARNING
Danger from dust that is harmful to your health
Respiratory sicknesses through inhalation of dust.
Do not vacuum without correctly installed filter ele-
ments, otherwise a danger to health from increased fine
dust emission is present.
14
ATTENTION
Danger due to fine dust entering
Risk of damage to the suction motor.
Never remove the flat fold filter when vacuuming.
1. Connect the suction hose and attach a suction noz-
The horn sounds when the air speed drops below 20 m/
s.
Note
The horn reacts to a vacuum.
1. Set the turn switch to the correct hose cross-section.
Static charges are discharged through the earthed con-
nection nozzles. This prevents sparking and electric
shocks with electrically conducting accessories (option-
al).
● The unit is equipped with a safety filter bag with
Note
6.904-364.0
All types of dust up to dust class H can be vacuumed
with this device. The use of a dust collection bag (for or-
der no. see filter systems) is required by law.
Note
The device is suitable for industrial extraction and a dust
6.904-420.0
removal device for mobile operation for vacuuming dry,
non-inflammable dusts with workplace limit values
(AGW).
● Unused flat fold filters may only be stored and trans-
● The slats of the flat fold filter many not be touched
Danger from dust that is harmful to your health
Respiratory sicknesses through inhalation of dust.
Do not vacuum without a flat fold filter and safety filter
bag, otherwise a danger to health from increased fine
dust emission is present.
1. Unlock and remove the suction head.
2. Attach the safety filter bag.
3. Put the safety filter bag over the container and insert
4. Fit and lock the suction head.
Danger from dust that is harmful to your health
Respiratory sicknesses through inhalation of dust.
No dusts harmful to health may be vacuumed when per-
forming wet vacuum cleaning.
1. Remove the brush strip.
2. Install the squeegees.
Note
The structured side of the squeegees must face out-
wards.
English
zle or connect to the dust generating device, de-
pending on the operating mode.
Horn
Anti-static system
Dry vacuuming
sealing cap, order number 6.904-420.0 (5 pieces).
ported in their packaging (cardboard box).
during installation.
Illustration C
WARNING
Installing the safety filter bag
Illustration D
the inner paper filter bag into the container in an L-
shape.
Illustration E
Wet vacuum cleaning
DANGER
Installing the squeegees
Illustration F