CRS-WD-TA869
7. Fit the top of the housing onto
the housing base.
8. Install the magnet. Ensure the
magnet switch and magnet are in
the correct position. The
Carephone will only be notified if
the magnet is detached from the
detector.
Distance between the magnet
switch and magnet ≤ 13 mm
Bosch Security Systems
9. Fit the magnet cover.
Connecting External
Contacts
There is a zone input in the
Wireless Contact Detector for the
use of external contacts.
When an alarm signal comes from
this connection, the Wireless Contact
Detector sends an alarm to the
Carephone or resets the activity
monitoring function.
Connection options for the zone
input:
Normally
open contact
(potential free)
Length of connection cable max. 3 m
Installation Manual
Installation Manual | en 15
Normally
closed contact
(potential free)
2.21 kOhm
2,21kΩ ±1%
±1%
(im Beipack)
(included)