Test of the photocells
In order to achieve a safer operation for the user, the unit performs a
photocells operational test, before a normal working cycle.
If no operational faults are found, the door starts moving.
Otherwise, it will stand still and the flashing light will stay on for 5 sec.
The whole test cycle lasts less than one second.
WARNING: V2 suggests to keep activated the test of the
photocells in order to grant a higher safety of the system.
WARNING: If the Foto menu is set to Ch, the photocell test
must be disabled.
Safety ribbon input
This menu allows the enabling of the safety ribbons and the
setting of their operation logic (see paragraph "Installation").
no
Input disabled (ignored by the control unit).
No jumper with the common is required.
AP
Input enabled only in opening phase
Ch
Input enabled only in closing phase
AP.Ch
Input enabled in opening and closing phase
Test of the safety edges
This menu allows setting the method of control of the safety edges
working.
no
Test disabled
rESi
Test enabled for conductive rubber safety edges
Foto
Test enabled for optical safety edges
WARNING: V2 suggests to keep activated the test of the
photocells in order to grant a higher safety of the system.
65