9.5.2 Error Messages

Symbol
CANBUS ERROR
EMERGENCY STOP
ACTIVATED
GENERIC INVERTOR
ERROR
GENERIC........ ERROR
(error code)
HEATSINK
TEMPERATURE HIGH
INVERTER OVERLOAD
LEFT DRIVE MOTOR
VOLTAGE LOW / RIGHT
DRIVE MOTOR
VOLTAGE LOW
MOTOR NOT
CONNECTED
MOTOR OVERHEAT
MOTOR OVERLOAD
MOTOR SHORT
CIRCUIT
D002998, 02.00
Error Message
Fault description
Error on CAN bus.
Emergency stop
activated.
Generic error converter,
radio, left/right drive
motor.
Generic error converter,
radio, left/right drive
motor.
Cooling flange for
frequency converter is
overheated.
The converter is
overloaded.
Low voltage left drive
motor.
Break in grinding
motor/grinding motor
cabling.
Grinding motor is
overheated.
Grinding motor becomes
overloaded. Overload
meter up to 100%.
Grinding motor
short-circuited.
Troubleshooting
Action
Check cabling. Check
units connected to
HMI.
Reset emergency stop.
Check the remote
control and reconnect
radio with the
connection button. See
Radio Control Radio
Control page
0
Go to the HTC Support
website.
Go to the HTC Support
website.
Let the frequency
converter cool down.
Let the machine cool
down.
Check control voltage.
Check battery voltage.
Check cabling to drive
motors. Check voltage
on relay outputs.
Check grinding motor
cabling. Check
measure grinding
motor.
Let the motor cool
down.
Let the machine cool
down.
Check grinding motor
cabling. Insulation
measure grinding
motor.
61