Electrical Considerations
All wiring should be done by a qualified electrician and
shall be in compliance with all local, city and state building
codes. Before making the electrical connection, make sure
that the main power supply is disconnected. The fireplace,
when installed, must be electrically grounded in accordance
with local codes, or in the absence of local codes, with the
National Electrical Code ANSI/NFPA 70 (Latest Edition).
A factory installed junction box is located on the lower right side
of the fireplace. The junction box and wiring may be relocated to
the opposite side of the fireplace if desired. Wiring to the junction
box must be metal clad or enclosed in a conduit and must be
approved for outdoor use. Connect the wiring to an external GFI
protected outlet installed near the fireplace. See Figure 10.