Dutch originals DO-CH-ACON120 Manuel D'utilisation page 17

12000 btu
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5) TROUBLESHOOTING
Symptom
√ Check the plug connection.
√ Check if the water level indicator lights
The device is
not operating
up.
√ Check the room temperature.
√ Check the air filters for dirt.
√ Check if the air exhaust is blocked.
√ Check if the room temperature is too low
The device
or too high.
does not
cool as set
√ Set temperature is higher / lower than
current temperature.
√ Overflow while moving the device.
Water
√ Check if the drain hose is kinked or bent. Straighten the drain hose to
leakage
√ Check if the device is securely positioned. Place the device on a horizontal
Excessive
√ Check for any loose or vibrating parts.
noise
√ Noise sounds like water flowing.
√ Communication faults between the
E0
device main PCB and display.
√ Temperature sensor failure
E1
Error
√ Humidity sensor dampened or failure.
E2
codes
√ Condensate water high level alarm.
Ft
5) SPECIFICATIONS
• Voltage input: 220 - 240 Vac – 50 Hz
• Class: I
• Rated input/power cooling: 1340W/5.8A
• Fuse type and rating: T-Type, 250 Vac, 3.15A
• Cooling capacity: 12.000 BTU
• Sound level: ≤ 65 dB(A)
• Maximum refrigerant charge: R290/250g
• Maximum suction / exhaust side working pressure: 0.7 Mpa/3.2Mpa
• Minimum room size: 12 M2 (floor area)
• Dimensions: 80.6 x 37.3 x 40.1 cm (H x D x W)
• Weight: 28 Kg
Inspection
EN 15
Solution
Insert the power plug securely
into the power socket.
Empty the water tank (drainage)
and reinstall correctly.
The range of operating
temperature is 5 - 35°C.
Clean the air filter.
Clear it from any obstacles.
This is normal. Allow more
time for cooling down when the
device is first turned on.
Set the temperature at proper
set-point according to the
manual.
Empty the water tank (drainage)
before transport.
avoid the creation of a trap.
and firm surface.
Secure and tighten the parts.
Noise comes from flowing
refrigerant. This is normal.
Contact the reseller.
Contact the reseller.
Contact the reseller.
Empty the drain pan by
removing the rubber plug from
the drain opening.