36" ELECTRIC RANGE INSTALLATION INSTRUCTIONS
• The appliance can be moved with a hand dolly or
with a clamp lift truck (not with a fork lift truck) only
if it is still packaged.
• Wear gloves to avoid cutting fingers on sharp
edges during installation.
• Remove the outer carton and packing material
from the shipping base.
• Before moving range ensure legs are installed
completely.
• Due to its weight, after removing the packing
material, move it with the help of a second person.
• The floor under the legs should be protected
(wood, strips, carpet, paneling, etc.) before push-
ing the unit into position.
• The anti-tip device must be installed, and the elec-
trical connection should be made before the range
is placed in its final position.
• Legs should be installed near to where the appli-
ance will be used as they are not secure for long
transit. Keep the unit raised so that the legs can
be screwed into their couplings, then lower the
range gently to prevent the legs and mounting
hardware from being subject to any undue strain.
NOTE: First insert the front feet and then the rear
ones.
The following is the correct order of installation and
positioning:
1. Install and adjust the legs.
2. Install the front/side skirting.
3. Assemble and fix the anti-tip bracket to the floor
or wall.
4. Connect the plug to the grounded outlet.
5. Move the range to its final position.
The adjustment range of the screw is 1.37 inches
(35 mm).
The appliance must sit level on the floor to ensure
stability:
• Screw or unscrew the bottom part of the foot until
the appliance is stable and level on the floor.
NOTE: this appliance must only use the specific
leveling legs provided by the manufacturer.

Electrical connection

Electrical shock hazard
WARNING
• This appliance is equipped
• The grounding prong must
Failure to do any of the above
could result in a fire, personal
injury or electrical shock.
7
with a four-prong grounding
plug for your protection
against electric shock and
should be plugged directly
into a properly grounded
receptacle. Do not cut or
remove the grounding prong
from this plug.
be plugged into a matching
grounding type receptacle
and connected to a correctly
polarized 240-Volt circuit. If
there is any doubt as to
whether the wall receptacle
is properly grounded, have it
checked by a qualified elec-
trician.