Spare Parts; Technical Information - THERMOBILE IMAC Manuel De L'utilisateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

English
Fault
The burner will
33
start, a flame has
been formed, but
34
the burner stops.
The convector
35
heater cannot be
switched off.
The convector
36
heater stops
The convector
37
heater stops
burning. The reset
38
button lights up.
39
Burner
40
malfunction: the
indicator light (red)
is on.
Write down the maintenance information in
table A in the Appendix at the back of this manual.
7

SPARE PARTS

Before use, we recommend you have spare parts
in stock. Refer to the Service manual for details.
8

TECHNICAL INFORMATION

For technical specifications, refer to the
tables B in the Appendix at the back of this
manual.
14
Cause
The ionization probe is
malfunctioning or is defective.
There are problems with the
polarity or the connection to
earth.
The magnet valve or valves will
not close.
An overheating problem has
occurred in the convector heater.
The fuel-supply line or the fuel
filter is leaking.
The protective grill of the air inlet
is dirty or clogged.
The heat exchanger is blocked.
There is no fuel.
The ionization probe is dirty.
The ionization probe is defective. Replace the ionization probe.
40.020.956 - rev. 03 - 2010
Solution
Check the ionization probe.
Clean or replace if necessary.
Check the electrical
connections. Correct if
necessary.
Close the shutoff valve of the
fuel supply. See fig. 5 & 8 (Q) or
Contact your dealer.
Reduce the resistance at the
outlet.
Reset the thermostat.
Contact the dealer if the error
recurs.
Check and replace if necessary. User
Clean the grill.
Clean the heat exchanger.
Check whether the valve in the
fuel supply is open.
Clean the ionization probe.
Action
Dealer
User
User
User
User
User
Dealer
User
Dealer
User
User
Dealer
IMAC - IMA - G US