2.4
Main components IMA (fig. 6)
A
Rain cover
B
Burner
C
Identification plate
D
Lifiting eye
E
Flue connection
F
Fan (radial) with motor
G
Heat exchanger
H
Burner chamber
I
Gas block with magnet valve
J
Pressure regulator
K
Fuel supply shutoff valve
L
Fork-lift guides
M
Push bar frame
N
Operating panel
2.5
Main components of the burner
(fig. 7)
A
Reset button burner relay (can also be reset
from the operating panel on the control
cabinet)
B
Burner relay
C
Ignition transformer
D
Gas test point and combustion head setting
E
Burner head with distributor head, mixing
plate, ingnition elektrode and ionization probe
F
Air shutter
G
Burner motor
H
Air switch
2.6
Operating panel IMAC (fig. 10)
A
Indicator light, blue: Ventilator is running
B
Indicator light, white: Panel is live
C
Indicator light, orange: Burner in operation
D
Hour counter
E
Digital thermostat
F
Pushbutton with indicator light, red: Burner
reset
G
Indicator light, red: Fan overload
H
Door lock
I
Indicator light, red: High temperature
J
Rotary switch for fan and burner:
-
0: The convector heater is switched off
-
1: The fan runs continuously
-
2: The fan runs in heating position
2.7
Operating panel IMA (fig. 11)
A
Rotary switch:
-
0: The heater is switched off
-
1: Ventilate
-
2: Ventilate automatic and heat
-
3: Ventilate continue and heat
B
Digital thermostat
C
Reset maximum thermostat
D
Connector for room thermostat
IMAC - IMA - G US
2.8
The digital thermostat (E) has three functions:
Fan thermostat:
The thermostat will switch on the main fan as
soon as the convector heater has reached
the preset temperature.
After switching off the convector heater, the
fan will continue to run. The fan will cool
down the convector heater to prevent
damage by overheating. The fan will
automatically stop.
Burner thermostat:
The thermostat will stop the burner as soon
as the temperature of the hot air has risen too
much.
When the air temperature has dropped
sufficiently, the thermostat will turn on the
burner again.
Maximum thermostat:
The maximum thermostat will switch off the
convector heater completely if an
overheating problem has occurred in the
convector heater. The burner cannot be
switched on again until the thermostat has
been reset by pressing the U key for two
seconds.
2.9
Thermostat for room temperature
Air supply hose (diameter 2 ft)
Fresh-air connection for the burner.
3
3.1
1.
Remove the packaging material from the
convector heater.
2.
Lift the convector heater to transport it to its
location of use.
3.2
1.
Make sure the convector heater is levelled
horizontal.
Connect the fuel supply to the gas train (Q) of the
convector heater. See fig. 5 & 8.
2.
Make sure there is sufficient distance
between the wall and the air inlet. Minimum
distance is 4 ft.
40.020.956 - rev. 03 - 2010
Digital thermostat

Accessories

PREPARATIONS

Removing the packaging
Caution
Lift the convector heater according to
the instructions in chapter 1.
Installation
Caution
Use only natural gas of the family I2H
and propane of the family 13P.