English
Fault
The heater triggers a
fault; the red lamp on
the operating panel
lights up.
The heater burns too
much gas.
The heater cannot be
switched off with the
switch.
The heater has a
fault: the red lamp on
the temperature con-
troller RE-THA6 is
on.
Record the maintenance details in table A in
the annex at the back of this manual.
7

SPARE PARTS

Contact the dealer for the use of spare parts.
22
Cause
9
The ionisation electrode
is dirty.
10 The pressure switch
does not switch the
heater off.
11
The pressure switch is
defective.
12 The ignition is not func-
tioning.
13 There is a leak between
the gas cock and the
gas regulator block.
14 The gas regulator block
does not shut off.
15 The temperature con-
troller is defective.
40.020.954 - rev. 05 - 2017
Solution
Clean the ionisation elec-
trode with steel wool.
Check if the combustion air
fan is rotating.
Check if the suction grid is
dirty.
Check if the supply of com-
bustion air is sufficient.
Check the pressure switch
and replace if necessary.
Check the connection
between the transformer and
the electrode for a short cir-
cuit.
Remove any short circuit that
is found.
Check the setting of the elec-
trode, for AGA 100 see fig. 9,
for AGA 102 see fig. 10
Shut off the gas supply.
Repair the leak.
Shut off the gas supply and
let the flame burn out.
Disconnect the mains con-
nection.
Check the gas regulator
block.
Repair or replace the temper-
ature controller.
Action
User
User
User
User
Dealer
User
User
User
Dealer
User
User
Dealer
Dealer
AGA 100/102