5

MAINTENANCE

5.1

Maintenance table

Use the table in this manual to record the
maintenance after each winter.
Description
Remove dust and deposits from the heater.
Check the heater (in a clean environment).
Check the heater (if in a dusty environment).
Check and clean the suction inlet for the combustion air
(AGA 102).
Check and clean the inlet grate.
Check the hot air fan for operation and damage (AGA
102).
Check the heater for correct combustion. The flame
must be blue. If the flame is yellow, consult the dealer.
Clean the ionisation electrode with steel wool.
Check the adjustment of the ionisation electrode and
adjust as necessary, see "Adjusting the ionisation elec-
trode".
Check the heater's wiring.
Hot
Do not touch the outlet or combustion
chamber!
Do not start maintenance until they
have cooled down.
20
/i
5.2
For long-term storage of the heater:
1. Switch off the heater.
2. Remove the mains plug from the socket.
3. Clean the heater.
40.020.954 - rev. 05 - 2017