CASTER EQUIPPED CHARBROILERS
Charbroilers mounted on stands with casters must use a flexible connector (not supplied)
that complies with the Standard for Connectors for Movable Gas Appliances, ANSI Z21.69
• CSA 6.16 and a quick-disconnect device that complies with the Standard for Quick-
Disconnect Devices for use With Gas Fuel, ANSI-Z21.41 • CSA 6.9. In addition, adequate
means must be provided to limit movement of the broiler without depending on the
connector and the quick-disconnect device or its associated piping to limit broiler
movement. Attach the restraining device at the rear of the charbroiler. If disconnection of
the restraint is necessary, turn off the gas supply before disconnection. Reconnect the
restraint prior to turning the gas supply on and return the charbroiler to its installation
position.
Note: If the Charbroiler is installed on casters and is moved for any reason, it is
recommended that it be re-leveled (see LEVELING).
OPERATION
The charbroiler and its parts are hot.
Use care when operating,
cleaning or servicing the charbroiler.
OFF
ON
CONTROLS
Fig. 5
CONTROL KNOBS
Each burner is independently controlled by an infinite heat control valve. Once the pilots
are lit, turning the control knob to the ON position will light each burner. The burners will
be in the full ON position when the control knobs are turned all the way to the left. The
burners will be in the full OFF position when the control knobs are turned all the way to
the right. See Fig. 5.
There is one pilot for each burner.
The charbroiler is equipped with standing,
unmonitored pilots. Gas will flow from the pilots as soon as the main gas supply to the
unit is turned on.
Standing pilots should be adjusted to provide a slight yellow tip on the flame. Air shutters
on the main burners must be individually adjusted to provide a blue flame. All traces of
yellow should be adjusted out of the burner flame.
The charbroiler is a free vented appliance.
All products of combustion and the heat
generated by the burners pass through the grates. When meat is placed on the grates,
this blocks the venting and causes a temperature build-up.