LEVELING
It is important that the charbroiler is level front to back and left to right. Areas of uneven
heat distribution will occur on an unleveled unit.
adjustable legs. Turn the feet at the bottom of the legs to adjust to level. The unit should
be rechecked for level anytime it has been moved.

VENTILATION HOOD

The broiler should be installed under a suitable ventilation hood. For safe operation and
proper ventilation, keep the space between the charbroiler and vent hood free from any
obstructions.

GAS CONNECTION

All gas supply connections and any pipe joint compound must be resistant to
the action of propane gases.
Purge the supply line to clean out any dust, dirt, or any foreign matter before connecting
the line to the unit.
Codes require that a gas shut-off valve be installed in the gas line ahead of the
charbroiler. The gas supply line must be at least the equivalent of ¾" iron pipe.
60" and 72" models have a gas inlet at each end of the unit. The unit will arrive from the
factory with a metal cap on one end and a dust cover on the other. You may move the
metal cap to the other end and use which ever connection point is most convenient to the
available supply outlet. Do not connect both of the available charbroiler gas inlets to the
gas supply.
A pressure regulator is supplied and must be installed outside of the broiler when making
the gas supply connection.
Natural Gas — 10"WC (Water Column) for Propane. Use the
manifold for checking pressure.
obstructions, dirt, and piping compound.

COMPONENT PARTS

The charbroiler comes with several standard parts as
illustrated. Each can be easily removed and installed easily
by hand for cleaning and maintenance. Note that the Burner
and Deflector are an assembly and are NOT designed to be
disassembled.
Standard orifices are set for 5"WC (Water Column) for
Make sure the gas piping is clean and free of