Heating time
The heating time can be changed by pressing the Heating time button. The corresponding
indicator light will start blinking indicating that it is possible to change the value. The setting is
changed with the Arrow up and Arrow down buttons.
Accept the changes by pressing OK, whereupon the setting will be stored in the operation
memory and permanent EEPROM memory. The indicator light will remain lit.
The factory setting is 2 h, maximum setting 6 or 12 h.
The unit will recall the set time and recommend it the next time that settings are being made.
Heating time can be changed while the timer is running:
Press the Heating time button – the corresponding indicator light will start blinking and the
setting can be made using the arrow buttons.
The hour and minute divider will not blink while making the setting, because the timer is
stopped when making changes to settings.
If you do not accept the changes by pressing OK within 5 seconds of the last button entry, the
change will not be recorded and the timer will resume from its last value.
The display will show the measured sauna temperature.
If you accept the changes by pressing OK within 5 seconds of the last button entry, the change
will be recorded and the new setting will appear in the display for 5 seconds, the timer's
hour/minute divider will begin to blink, and the indicator light will come on, until the sauna room
temperature appears in the display.
Temperature
The temperature can be changed by pressing the Temperature button. The corresponding
indicator light will start blinking indicating that it is possible to change the value. The setting is
changed with the Arrow up and Arrow down buttons.
Accept by pressing OK, whereupon the setting will be stored in the operation memory and
permanent EEPROM memory.
The factory setting is 80°C, maximum setting 110°C.
The user setting range is 0-110°C.
The unit will recall the set temperature and recommend it the next time that settings are being
made.
The temperature can be changed during the sauna run time:
Press the Temperature button – the corresponding indicator light will start blinking.
The temperature setting will appear in the display and the setting can be made using the arrow
buttons.
If you do not accept the changes by pressing OK within 5 seconds of the last button entry, the
change will not be recorded and the previous setting value will remain valid. The display will
show the measured sauna temperature.
If you accept the changes by pressing OK within 5 seconds of the last button entry, the change
will be recorded, the new setting will appear in the display for 5 seconds and the indicator light
will come on, until the sauna room temperature appears in the display.
Light and fan
Press once to start function and press again to stop.
The corresponding indicator lights will come on when pressed.
These buttons are always operational when the unit is connected to the power supply (ie. both