Installation; Installing The Outside Station; Installing The Monitor; Rfid Initialisation (Access Version Only) - Extel STEP ACCESS Guide D'installation Et D'utilisation

Rfid videophone
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 4
Access: Only available with the STEP Access version
11. RFID reading zone
12. RFID reset button
Caution: make sure to follow the instructions in Chapter 9 on page 11
13. Switch to change the "Access" function (gate (A) or electric latch (B))

4. INSTALLATION

Note:
If you try the system before installing it, make sure the outside unit and monitor are not in the same room,
otherwise the videophone will emit piercing feedback noise (Larsen effect)
a. Installing the outside station
(fig. 5)
1. Remove the screw under the outside station
2. Tip the outside station forward
3. The panel lens must be placed at a height of about 1.60 m.
4. Place a silicone seal between the shield and the wall to avoid water running inside. *Do not use acetic acid
based silicone (vinegar smell).
5. Solidly fix the rain shield using the screws (5).
6. For the products with the "Access" option, select the opening mode for the RFID function (electric latch or
gate) using the switch (fig 3 - 13)
7. Connect the wires according to the wiring diagram (fig. 6).
8. Engage the outside station onto its rain shield
9. Refit the fixing screw
Important : Do not point the video camera directly at the sun or at reflecting surfaces.
Tip: we recommend passing the cables through a protective sleeve to protect them from impacts and the
weather.
b. Installing the monitor (fig. 4)
1. Fasten the wall mounting (2) so that the monitor screen is at a height of about 1.60m.
2. Connect the two outside station wires and the 2 power supply wires (ch. 5.a) according to the wiring diagram
(fig. 6 for a basic installation)
3. Position the monitor on its wall mount.
4. Only connect the 230 V~ power supply to the modular adapter after having connected the outside station (on
an installation compliant with applicable standards: BS 7671 in the UK)
Please, reserve 5cm each side of MODULO B when install
Make sure the power supply polarity is correct
c. RFID initialisation (for STEP Access only)
When powering on for the first time, it is essential to configure the badges in the following order:
1. Press the reset button on the outdoor station, the station issues 5 short beeps.
2 Pass the administrator badge
, a short beep confirms the programming.
3. Pass badge
, a short beep confirms the programming.
4. Pass badge
, a long beep confirms the end of administration badge programming.
d. Installing the extra camera (option)
• Connect the wires according to the wiring diagram (fig. 6)
• Choose a suitable location to install the camera.
• Make sure nothing interferes with the installation.
• Screw the wall part using the supplied screws
• Screw the camera onto the support
• Point the camera in the required direction and tighten the holding screw on the side.
• Connect the camera to the videophone system
CFI EXTEL STEP - STEP ACCESS - 03/2017
GB3

Hide quick links:

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

LevoLevo accessStep access

Table des Matières