ACTIVATION INPUTS

City1 control unit is equipped with two activation inputs, whose
operation depends on the programmed operation modes (see
Strt item of programming menu):
• Standard mode: a command being on the first input will
cause the complete opening of both leaves (start); a
command being on the second input will cause the partial
opening of leaf 1 only (pedestrian start).
• Open/Close command and manned operation: a command
on the first input always controls the gate opening, while a
command on the second input always controls the gate closing.
In Open/Close mode, there is an impulse command, that is
to say that an impulse will cause the complete gate opening
or closing.
In manned operation, there is a monostable command, that
is to say, the gate will be opened or closed as long as the
contact is closed and it will immediately stop as the contact
is open.
• Timer mode: it is similar to the standard mode but the gate
stays open (completely or partially) while the contact is
closed on input; as soon as the contact is open the pause
time count down will start, after which the gate will be
closed again. This function allows programming the gate
opening time during the day, by making use of an external
timer. Automatic closing must be enabled.
In all modes, inputs must be connected to devices having
normally open contacts.
Connect cables of device controlling the first input between
terminals 3 and 6 of the control unit.
Connect cables of device controlling the second input between
terminals 4 and 6 of the control unit.
The first input function can also be activated by pressing UP
key outside the programming menu or by means of a remote
control stored on channel 1 (see relevant instructions of MR1
receiver).
The second input function can also be activated by pressing
DOWN key outside the programming menu or by means of a
remote control stored on channel 2.

PLUG IN RECEIVER

City1 control unit is suitable for plugging in a Personal Pass
MR1 receiver having a high-sensitivity super-heterodyne
architecture.
WARNING: it is necessary to turn off the control unit
power before doing the operations mentioned here below. Pay
attention to the way you connect the removable modules.
MR1 module receiver is provided with 4 channels and each of
them is suitable for a command of City1 control unit:
• CHANNEL 1
START
• CHANNEL 2
PEDESTRIAN START
• CHANNEL 3
STOP
• CHANNEL 4
OPTIONAL MODULS OUTPUT
WARNING: Before programming 4 channels and function
logics read carefully the instructions of MR1.

EXTERNAL AERIAL

We suggest to use the external aerial (model: ANS433 or
ANSGP433) in order to guarantee the maximal range.
Connect the antenna hot pole to terminal 1 of the control unit
and the braiding to terminal 2.