V2 ELETTRONICA City1 Mode D'emploi page 13

Centrale de commande numérique pour portails à vantails et coulissants
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Motor 2 power
This menu allows adjusting the motor 2 power.
The displayed value is the percentage of max. motor power.
WARNING: In case an hydraulic motor is used, set value 100.
Start off
When the gate is standstill and it begins moving, the initial inertia
must be faced, therefore, if your gate is quite heavy, its doors could
not move.
In case the SPUn (pickup) function is activated, for the first 2 seconds
of motion of each door, the control unit will ignore both Pot1 and Pot2
values and it will give motors the maximum power command in order
to overcome the gate inertia.
Soft start (slowed down)
In case this function is enabled, during the first seconds of motion of
each door, the control unit will give motors a reduced power
command, for a softer start.
Slowing down time
In case this function is enabled, during the last seconds of motion of
each door, the control unit will give motors a reduced power
command, to avoid a strong impact with the stop end. t.AP1 is the
max. allowed time.
WARNING:
• In case the self-learning function of working times is NOT used, we
recommend disabling the slowing down function in order to
measure both opening and closing times, and to enable it again once
the setup has been carried out. The control unit will automatically
consider the working time delay caused by the slowing down.
• If partial opening time t.APP is shorter than t.AP1, there will be no
slowing down during the pedestrian cycle opening.
Fast closing time after slowing down
If a slowing time other than 0 is set up, it could be likely that the gate
speed is not enough for the lock to fasten during the closing phase.
In case this function is enabled, once the slowing down phase is
finished, the control unit will give a normal speed command (that is to
say, with no slowing down) for the set up time, and then it will open
the gate for a second fraction, to avoid leaving the motor under stress.
WARNING: in case the gate has no electric lock, set the value 0.