V2 ELETTRONICA City1 Mode D'emploi page 15

Centrale de commande numérique pour portails à vantails et coulissants
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Automatic closing
During the automatic operation, the control unit will automatically
close the gate when a set-up time expires.
The Start command, if enabled by St.PA menu, allows closing the gate
before the set up time expires.
In semi-automatic operation, that is to say, if the automatic closing
function is disabled by setting the value to zero ('no' will be displayed),
the gate can be closed through the start command only: in this case,
St.PA menu setup will be ignored.
If the control unit receives a Stop command when the gate is in
pause, it will automatically pass to the semi-automatic operation.
Closing after transit
During the automatic operation, the pause count down starts from the
set up value each time a photocell operates during the pause.
If the photocell operates during the opening time, this time will be
immediately stored as pause time.
This function allows having a fast closing as soon as transit through
the gate is completed, therefore, a time shorter than Ch.AU is
generally used.
Ch.AU will be used when 'no' is set up.
As for semi-automatic operation, this function is not active.
Pause after transit
In order to let the gate open for the shortest possible time, it is
possible to stop the gate once the passage before the photocells is
detected. If the automatic working is enabled, the time of the pause is
Ch.tr.
If the photocells are type 1 and type 2, the gate enters the phase of
pause only after the detections before both the photocells.
Blinker during pause time
Blinker usually operates during the gate motion only; however, if this
function is enabled, blinker will be on during the pause time too.
Start input function
This menu allows selecting input operation modes (see paragraph
"Activation inputs"):
StAn
Start and Pedestrian Start input standard operation,
according to menu setups.
no
Start inputs from terminal board are disabled. Radio inputs
operate in StAn mode.
AP.CH
Start impulse always controls the opening phase, Pedestrian
Start always controls the closing phase.
PrES
Manned operation; the gate will open as long as the Start
input stays closed and it will close as long as Pedestrian
Start stays closed.
oroL
Timer-operation; the gate stays open while the Start input or
Pedestrian Start input is closed; as soon as the contact
opens, the pause count down will start.
37
37

Publicité

Table des Matières
loading

Produits Connexes pour V2 ELETTRONICA City1

Table des Matières