Error Codes; Code Description; Corrective Action - DeWalt DW0165 Manuel D'utilisation

Masquer les pouces Voir aussi pour DW0165:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Error Codes

If INFO appears on the screen with a Code number, perform the corresponding Corrective
Action.
Code
Description
101
Received Signal Too Weak,
Measuring Time Too Long
102
Received Signal Too High
201
Too Much Background Light
202
Laser Beam Interrupted
301
Temperature Too High
302
Temperature Too Low
401
Hardware Error
402
Unknown Error
500
Data Error

Corrective Action

Use the target plate or change the target surface.
Target is too reflective. Use the target plate or
change the target surface.
Reduce the background light on the target area.
Remove the obstacle and repeat the measurement.
Allow the device to cool down to a temperature
within the specified Operating Temperature
Range.
Allow the device to warm up to a temperature within
the specified Operating Temperature Range.
Switch the device on/off several times. If the error
still occurs, return the defective device to the
Service Center or distributor. Refer to the Warranty.
Contact the Service Center or distributor. Refer to
the Warranty.
Contact the Service Center or distributor. Refer to
the Warranty.