Intended Use; Technical Data; Before Starting - EINHELL GC-DP 1340 G Mode D'emploi D'origine

Masquer les pouces Voir aussi pour GC-DP 1340 G:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

GB
Dirty water pump
n
Hose connection
n
Rope
n
Original operating instructions
n

3. Intended use

The equipment you have purchased is designed to
pump water with a maximum temperature of 35 °C.
This equipment must never be used for other liquids,
especially not for engine fuels, cleaning agents and
other chemically-based products!
Before you use the pump, clarify any possible special
conditions which need to be fulfilled for the
installation!
For example, additional safety measures may be
needed if damage to property could result from a
power failure, soiling or a defective gasket.
Examples of such safety measures:
Pumps running in parallel on a separately protected
power circuit, moisture sensors for switching off the
pumps, and similar safety arrangements.
Be sure to consult a professional plumber if you have
any doubt.
The equipment can be used wherever you want to
move water, e.g. in the house, in the garden, and for
many other applications. It must not be used to
operate swimming pools!
If you want to use the equipment in bodies of water
with a natural, muddy bottom, place the equipment in
a slightly elevated position, e.g. on bricks.
The equipment is not designed for continuous
operation, e.g. as a circulating pump in a pond. In this
case the equipment's anticipated life will be greatly
shortened because the equipment was not designed
for continuous loading.
The equipment may only be used for its intended
purpose. Any other use is deemed to be a case of
misuse. The user/operator and not the manufacturer
will be liable for any damage or injuries of any kind
which result from such misuse.
Please note that our equipment has not been
designed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
equipment is used in commercial, trade or industrial
businesses or for equivalent purposes.
12

4. Technical data

Mains connection
Power rating
Max. pumping rate
Max. delivery head
Max. submersion depth
Max. water temperature
Hose connection
Max. size of foreign bodies:
Switching point height: ON
Switching point height: OFF

5. Before starting

5.1 Installation
The equipment can be installed either:
Stationary with a rigid pipe line
n
or
Stationary with a flexible hose line
n
The equipment must be fastened with the supplied
rope (Fig. 1/Item 5) attached to the handle (Fig. 1/Item
1).
Note:
The maximum pumping rate is possible only with the
largest possible line diameter; if smaller hoses or
pipes are connected, the pumping rate will be
reduced. Flexible hose lines must be fastened to the
hose connection with a hose clip (not included in the
scope of supply).
Note!
When installing, never hang the equipment by the
discharge line or by the power cable. The equipment
must be hung up with the provided carry handle or it
must rest on the bottom of the shaft. To ensure that
the equipment works properly, the bottom of the shaft
always must be free of sludge and other
accumulations of dirt. If the water level is too low, the
sludge in the shaft can quickly dry out and hinder the
equipment from starting. It is necessary therefore to
check the equipment regularly (carry out trial start-
ups).
Note:
The pump shaft should be of sufficient size to enable
the floating switch to move freely.
230 V ~ 50 Hz
1300 W
23,000 l/h
10 m
5 m
35°C
approx. 59.6 mm (G 2) IG
Ø 40 mm
max. approx. 70 cm
min. approx. 20 cm