Over current protection system:

Your refrigerator has an over current protection system in the electronic circuit to prevent damage to the inverter which may occur due
to a reverse polarity connection.
If the refrigerator does not operate and the green power light does not come on, check the fuse, which is located in-line with the DC
connector, and the polarity of the DC power supply. If the refrigerator still does not operate, another problem can exist in the power
module. Have an authorized Norcold Service Center check the refrigerator.

Refrigerator Maintenance Checklist

Read and understand the following maintenance sections of this manual.
Norcold is not responsible for installation, adjustment, alteration, service, or maintenance performed by
NOTICE
anyone other than an authorized Norcold Service Center.
Have an authorized Norcold Service Center do these annual safety and maintenance checks:
- Make sure the AC and DC voltages are correct (See the "Electrical current necessary" section).
- The wire connections must be clean, tight and free of corrosion. If any of these items are not correct:
- A voltage drop to the refrigerator will occur.
- The voltage drop will decrease the cooling performance of the refrigerator.
Disconnect the positive (+) DC power supply wire from the battery before you do a "fast charge" of the
!
CAUTION
battery. Failure to disconnect the positive (+) power supply wire from the battery during a "fast charge" can
cause damage to the refrigerator or other 12 volt DC appliances.
- Make sure the area at the rear of the refrigerator is free of anything, especially combustible materials, gasoline, and other
flammable vapors and liquids.

Replacement Parts

You may purchase replacement parts through your dealer or an authorized Norcold Service Center.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified
!
CAUTION
persons in order to avoid a hazard.