11. Replacing the washer in the pressure reducer
The self-locking, maintenance-free Longlife washer in the connection socket
of the pressure reducer will normally function effectively over many years.
Should you be unable to produce a connection which does not leak despite
screwing on the pressure reducer several times (without canting!), the was-
her is presumably worn out and should be replaced.
• For this purpose, insert a small screwdri-
19
ver or similar behind the washer from
the side and carefully lever the washer
out.
Be careful not to damage the
connecting thread, the pressure pin or
the sealing surface! Be sure to verify
that no foreign matter (dust, dirt particles, metal chips, etc.) enters into
the opening of the pressure reducer!
• Blow air through the connection socket in order to clean it.
• Carefully press the new washer into position using a suitable, non-metal-
lic object. Be careful not to damage the washer and the connection
socket. Check that the washer is fitted correctly in place.
12. Examining the special CO
check valve
2
The check valve protects your valuable pressure reducer from corrosion cau-
sed by back-flowing water. It will operate reliably over a very long period.
However, as dirt, paint and metal particles may collect on the sealing sur-
faces over the course of time, the check valve should be examined every 2
years at the latest and replaced if necessary.
Examination procedure:
• Close needle valve on CO
pressure reducer.
2
• After 24 hours, unscrew the coupling ring on the side of the check valve
facing the pressure reducer.
• Pull off CO
hose and check whether any water has entered into the
2
hose. If so: Replace check valve. If not: Reconnect hose to check valve.
• Reset number of bubbles.
Don't worry: An effectively functioning aquarium will normally have no pro-
blem coping without a CO
supply for 24 hours
2
Important note: Use only check valves designed for use with CO
the special CO
check valve from DENNERLE. Standard air check
2
valves may become brittle through contact with CO
within only a short
2
space of time, resulting in leaks. This usually goes unnoticed.
13. Replacing the special CO
indicator
2
Like most colouring agents, the indicator is subject to ageing as a result of
photochemical processes. In order to guarantee the quickest and most exact
colour response at all times, we thus recommend filling the test container
with fresh special CO
indicator every 4 weeks.
2
For this purpose, open the test container and pour the old indicator down
the drain. Rinse test container with tap water and dry with a kitchen cloth
or similar before refilling.
14. Cleaning the CO
long-term test
2
Use warm water and a soft sponge. Do not use any cleaning agents!
The test container can be dismantled for cleaning. If necessary, grease the
two O-rings slightly (!) with Vaseline (from a pharmacy, drugstore) before
re-assembling the test container.
18
IMPORTANT: Do not use any other lubricants, as these may lead to incorrect
colour indications.
15. Cleaning the CO
Flipper
2
20
• Take CO
FLIPPER out of the aquarium.
2
• Extract CO
collector vertically.
2
• Place CO
Flipper into your left hand, so
21
2
that the suction cups point towards the
right. The open side (which holds the
collector) points upwards.
• Slide front side wall of the Flipper
upward by approx. 2 cm.
• Remove the side wall.
22
• Remove the CO
• Now clean all components of the CO
Flipper with warm water and a soft
sponge. Do not use any detergents.
23
• Reassemble the Flipper in reverse order.
Attention: reinsert the CO
side wall so that the lower end is at the
very bottom of the reactor.
What if ... – Troubleshooting
Fault
Cause
, such as
2
A faint hissing sound is
Pressure reducer is
to be heard at the scr-
skew or has not been
ewed connection bet-
screwed in tight
ween pressure reducer
enough.
and CO
cylinder.
2
Washer in the connec-
tion socket of the
pressure reducer is
defective.
No bubbles on the CO
CO
cylinder empty.
2
2
Flipper.
Needle valve closed.
Hose connection lea-
king.
Fault
CO
bubbles issue
2
from the hose but do
not rise, or do not rise
any further after the
first step.
Bubbles bob around in
the water, but do not
rise.
Gas escapes from the
side of the CO
21
Flipper's collector.
22
hose, do not pull it out.
2
2
CO
bubbles no longer
2
rise unhindered on the
steps of the CO
Flipper.
hose into the
2
23
Upgrade options
Level 1: The DENNERLE CO
trolled by a time switch and cuts off the CO
plants do not consume any CO
Remedy
Level 2: The DENNERLE pH controller 588 Digital Comfort mea-
sures the pH value in the aquarium continuously and controls the
Unscrew pressure
CO
supply precisely and fully automatically via the CO
2
reducer and screw in
cut-off valve Comfort.
place again hand-
tight without can-
Professional tips from DENNERLE:
ting.
• Large quantities of valuable CO
CO
hoses. We thus recommend the special Softflex CO
2
Fit new washer (see
from DENNERLE.
above).
• Even when using CO
nevertheless expedient to install an additional bubble counter close to
the pressure reducer. This enables the number of bubbles to be set even
more simply, quickly and exactly. The DENNERLE CO
Replace CO
cylinder.
2
counter Exact offers the ultimate in user-friendly reading coupled
with exceptional precision: The CO
Open needle valve.
counter Exact have a mean weight of 0.125 mg and a volume of 0.063
ml. 10 bubbles per minute thus correspond to a CO
Check hose connection,
0.9 litres per day.
replace if necessary.

Special information

Cause
Remedy
• Keep CO
Operating pressure
Set operating pressu-
• The special CO
too low.
re to approx. 1 bar.
solvents. Prolonged skin contact and eye contact should nevertheless be
avoided.
CO
Flipper is not fit-
Fit CO
Flipper in an
2
2
• The indicator may cause stains. Contact with clothing, carpets, wood or
ted in an upright posi-
upright position.
similar should thus be avoided.
tion.
• Any indicator which may be dropped into the aquarium water by mista-
CO
Flipper is still in
Await end of running-
ke is harmless for all fish, plants and any other creatures living in the
2
the running-in phase.
aquarium.
in phase.
• The ampoule is filled with special CO
Water is too agitated.
Restrict movement
phere. The filling level may vary for technical reasons.
of the water or fit
• Protect the special CO
Flipper at a calmer
keep ampoules protected from light during storage.
point.

Technical data

CO
Flipper is not fit-
Fit CO
Flipper in an
2
2
Disposable CO
ted in an upright posi-
upright position.
2
In accordance with TRG 303 (German technical regulations for pressurised
tion.
gases). Test number issued by TÜV technical control board: 057478/85.
Waste air vent on the
Clean CO
Flipper.
Capacity: max. 500 g of CO
2
CO
collector is dirty.
2
Volume: 930 ccm. Pressure: 36 bar (0 °C). Test pressure: 165 bar. Self-
closing cylinder valve. Connecting thread M 10 x 1.25.
CO
collector is skew.
Remove
collector
2
and refit correctly.
Pressure reducer Professional for Comfort-Line
Algae
formation,
Clean CO
Flipper.
Cylinder pressure manometer: 0 – 250 bar. Operating pressure manome-
2
small snails or accu-
ter: 0 - 6 bar.
mulation of sludge.
Adjustable operating pressure. Connection for hose 4/6 mm. Needle valve
2
with stainless steel needle and precision thread. Self-closing pressure-relief
valve.
Note: The CO
for the DENNERLE disposable CO
only be used with these cylinders. It is NOT permissible to operate the pres-
night cut-off valve Comfort is con-
sure reducer with reusable CO
2
supply at night, as
2
Warranty: 3 years from date of purchase (except wearing parts)
at night. This saves valuable CO
.
2
2

Spare parts and useful accessories

(available from specialist retailers)
3013 Disposable CO
night
2
3015 Comfort-Line CO
3029 2 washers for Comfort-Line pressure reducer
3043 2 Longlife suction clips, green
1484 Leak detector spray
may be lost every day through leaking
2
3060 Special CO
hose
2
3050 CO
3053 Special CO
diffusors with integrated bubble counter, it is
3041 Special CO
2
For further information on the range of aquarium plants and accessories
from DENNERLE, consult your dealer or check out DENNERLE's free profes-
bubble
2
sional tips!
DENNERLE professional tips are available from your dealer and on the inter-
bubbles produced by the CO
bubble
2
2
net at www.dennerle.de!
supply of 1.8 g or
Sales:
2
Customer service:
long-term test and indicator away from children!
2
indicator is harmless and does not contain any chemical
2
indicator under a protective atmos-
2
indicator from sunshine, heat and frost. Always
2
cylinder
2
. Tare weight: 1.16 kg.
2
pressure reducer Professional has been developed especially
2
cylinders of the Comfort-Line, and may
2
cylinders by means of an adapter.
2
cylinder, 500 g
2
pressure reducer Professional
2
Softflex hose, 2 m
2
bubble counter Exact
2
check valve
2
indicator, 5 ampoules
2
DENNERLE GmbH, D-66957 Vinningen
DENNERLE GmbH, D-66981 Münchweiler
www.dennerle.de
19

Publicité

Table des Matières
loading

Table des Matières