Install The Exhaust Duct; Accessories - Novy 7600/15 Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Place the exhaust pipe on a connection nozzle of the motor using aluminium tape or a hose clamp. Put the plug into
9
the wall socket. Take the two shaft parts and place them onto the wall-mounted chimney hood. Make sure that this
is done carefully in order to prevent the chimney hood or the shafts from being damaged. Clamp the shafts around
the lower spacer.
Open the bottom plate and remove the filter from the chimney hood. Tighten the shaft of the chimney hood with the
4 screws (906151) from the inside.
Pull out the upper shaft part towards the ceiling and clamp it behind the upper spacer. Then fasten the shaft on both
10
sides onto the upper spacer bracket using the 2 supplied stainless steel screws (906035).
MOUNT THE REMOTE MOTOR UNIT
For the models 7605 and 7615 the remote motor unit of the chimney hood is mounted. A choice can be made between
an internal motor, an external motor for outside mounting or a roof motor. With an external motor the minimum distance
between the hood and the external motor must be 5 metres. The hood is connected to an earthed wall socket. The hood
and the motor unit are electrically connected by means of a 6-pole plug connection. Additional information can be found
in the mounting instructions of the motor involved.

INSTALL THE EXHAUST DUCT

The exhaust of the hood must be properly taken care of. For optimum performance of the hood it is important to pay
attention to the following items during the installation:
• Use smooth, non-flammable pipes with an internal diameter that is equal to the external diameter of the connection
nozzle of the hood. Maximally extend flexible ducts and cut them to size.
• Do not reduce the exhaust diameter. This will lower the capacity and raise the noise level.
• Make the duct as short as possible and with as few as possible bends to the outside.
• Avoid square bends. Use rounded bends for proper air conduction.
• Flat duct: the surface of a flat duct must be the same size as Ø150 mm = 177 cm².
• In case of an exhaust pipe through the outside wall passing a cavity wall, make sure that the exhaust duct fully
bridges the cavity and slightly declines to the outside.
• When connecting to a short exhaust duct, it may be required to mount a non-return valve in the duct to avoid wind
blowing in.
• Use a hose clamp or aluminium tape for airtight connections.
• In case of an exhaust pipe through the roof, use a double-walled roof passage with sufficient width.
• Never connect to a flue duct.
• Make sure that sufficient air is supplied. Fresh air can be supplied by slightly opening a window or an outside door or
by installing an inlet grate.

ACCESSORIES

Recirculation
If you choose for recirculation, Novy offers the recirculation kit, type 7640400. This kit includes a recirculation box that is
mounted behind the upper shaft and a Monoblock recirculation filter.
Extension cable
When mounting the motor unit remotely, it may be desirable to mount a longer cable between the cookerhood and the
motor. The extension cable is connected to the existing cable. The extension cable has a length of 5m.