Serie TM / Serie PROTEC burglary central unit - User's manual
ATTENTION!
The 12V7Ah battery must always be connected. Ensure of its efficient charge state,
measuring the tension by a volt-meter, after disconnecting the main power supply from
the power supplier/battery charger by the sectioning switch. Also in case of changing of
the lead battery it's necessary to disconnect the main power supply from the power
supplier/battery charger, to avoid that the entire system burden on it.
Don't connect on 13Vcc services power supply output of the central unit (clamps [4] and
[5] "+12V") a load beyond 400mA (see pag.4).
After having connected the battery of the control unit and of the siren, you can proceed to
switch on the disconnecting-switch which connects the network voltage to the terminals of the
feeder.
For safety reasons and in respect to the current regulations we advise to carry out and
verify the link to an efficient ground system of all the systems that will need it(included the
metallic box of the TM control units)
The NET LED on the panel of the control unit signals the presence of the real network
tension.
2.3

Connections

The terminals of the TM400P, TM500P, TM900P, PROTEC4, POTEC9 control unit are
described in the following table.
+
Alarm
NA
C
NC
Sir
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
1 - 2 - 3
4 - 5
5 - 6
7 - 8
9 - 10
11 - 12
13 - 14
15 - 16
17
18
19 - 25
*
If the alarm zones are not used, the clamps must be arched.
22
-
-
+
+
-
12Vcc int12V Chiave
S.A.
Additional output contact relay
13Vcc output tension on system enabled for the telephone dialer enabling.
13Vcc output tension in alarm condition for supplementary indoor sirens and
telephone dialer activation.
13Vcc regular output tension for volumetric detectors, telephone dialer, etc.
ATTENTION! Maximun current supplied: see pag.4
13Vcc output tension on system enabled for the telephone dialer enabling.
Out-put in series to the key switch of the panel. Interrupting to connect
eventual command systems PX, SK, KB.
13Vcc output tension
systems.
(13) = Green LED
(14) = Red LED
Common clip for the zones
24h anti-sabotage protection zone
Zone
NC* line (immediated).
Zone
NC* line (delayed).
+
R
Com
V
led key
zone
(only TM500P, TM900P, PROTEC9).
to command the LED on
.
NC* line (immediated).
24H Z1
Z2
Z3 Z4 Z5 Z6 Z7 Z8
16 17 18 19
20
21 22 23 24 25
PX, SK or KB command
security