Introduction

1.
1
TM Series and PROTEC Series central unit description
The PROTEC Series and TM Series burglary central units, planned with microprocessor technology,
are to be used in the context of an antitheft protection system for residencial and trade places.
The TM Series burglary central units must be installed exclusively by using components of the
modular TM Series: they have to be installed in TM3, TM4 or TM4C boxes, with TM35SW power
supplier/battery charger.
The PROTEC4 and TM400P panel manage an antitheft system for 3 zones protection with one zone
for the anti-sabotage protection (24h); the TM500P panel manages 5 zones, with one anti-sabotage zone
24h; the PROTEC9 and TM900P panel manage an antitheft system for 8 zones protection more one zone
for the anti-sabotage protection (24h).
It centers them antitheft Series PROTEC and Series TM go used in coupling to magnetic sensors of
perimetrale protection, in coupling to volumetric detectors of presence, or whichever other sensor of type
NC. The alarm can be: sonorous/luminous, in autoalimentata coupling to the sirena for outside SA310;
sonorous, in coupling to the sirena piezoelectric for inner SP31; telephone, in coupling to telephone
combinatori TD92, TDC22, TDC30, ERMES or, for the panels only center them antitheft Series TM, in
coupling to a combinatore panel telephone TM92P, TM20GSM, TM60GSM, using container TM4C.
1.2

Operating features

System partialization by buttons.
System enabling/disabling by built-in mechanic key,or optional command systems
Auto-inhibition of every zones, if it not restored, after it had born an alarm.
Adjustable exit timing 4 ÷ 75 sec (PROTEC4, PROTEC9), 5 ÷ 90 sec (TM500P,TM900P).
Adjustable entrance timing
Adjustable alarm duration 180 ÷ 600 sec.
Control LED main:
Output:
Antiopening protection tamper.
Antitearing protection tamper (only PROTEC Series).
Operating temperature +5°C ÷ +40°C
4÷75 sec (PROTEC4, PROTEC9),5÷90 sec (TM500P, TM900P)
> PROTEC4 e PROTEC9:
> TM400P, TM500P e TM900P:
> TM400P e PROTEC4:
> TM500P, TM900P e PROTEC9:
voltage present,time of exit,alarm
s t a t e , z o n e s
memory,fusible state services
voltage,time of exit,alarm state,zone
state,alarm memory
activation sirens Ext/Int,positive
present of system activated
activated siren Ext/Int,positive present
to inserted,exited relè on alarm
Introduction
.
s t a t e , a l a r m
19