Installation instructions, only for experts
3. Connect the wires for the humidity sensor to the terminals labelled "+ S -"
in terminal strip 2.
c. Connect the green wire to terminal "+".
d. Connect the orange wire to terminal "S".
e. Connect the red wire to terminal "-".

5.10. Connecting the film sensor (optional)

1. Guide the wires for the sensor through the cable bushing 5 into the low-
voltage connection area 1.
2. Connect the wires for the sensor to the terminals labelled "FF" in terminal
strip 2.

5.11. Connecting the safety shut-off device

EN 60335-2-53 states that sauna control units with a remote start or preset timer
function may only be used for operating and regulating a sauna heater which
has satisfied the combustion test described in paragraph 19.101. Alternatively,
a suitable safety shut-off device can be installed in or above the heater. This shuts
the sauna heater off when objects, e.g. a towel, are placed on the sauna heater.
To install the safety shut-off device, perform the following steps:
1. Install the safety shut-off device in accordance with the operating instruc-
tions for the device.
2. Guide the wires for the safety shut-off device through the cable bushing 7
into the low-voltage connection area 1.
3. Connect the wires for the temperature sensor to the terminals labelled "OSG"
in terminal strip 2.
When the remote start function is deactivated, you may also use the
sauna control unit just sauna with a safety shut-off device. In this case,
bridge terminal "OSG" in the low-voltage connection area 1 using
a wire jumper.