Beyerdynamic MCS 20 Notice D'utilisation page 45

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

MCS 20 – MCS 223 Microphone Unit
No. Description
14
"FiFo" = "Requ" + "Free":
0 = MCS 223 does not turn off another microphone unit
1 = MCS 223 turns off another microphone unit
15
"FiFo" = "Requ" + "Free":
0 = MCS 223 is not turned off by another microphone unit
1 = MCS 223 is turned off by another microphone unit
16
Warning signal in the "Free" mode before the speech time has elapsed;
0 = no warning signal
17
After the speech time has elapsed in the "Free" mode
0 = Timer indicates the exceeded speech time (counts up)
1 = MCS 221 is turned off
18
Warning signal in the "Request" mode before the speech time has elapsed;
0 = no warning signal
19
After the speech time has elapsed in the "Request" mode:
0 = Timer indicates the exceeded speech time (counts up)
1 = Timer stops (activated MCS 221 is turned off and the registered MCS 221
must be activated by the chairman with the "Requ" button)
2 = Timer starts again (activated MCS 221 is turned off and registered
MCS 221 is turned on)
20
Speech time is displayed in minutes (applies to "Free" and "Request" mode
(no. 20 and 21 are added)
21
Speech time is displayed in seconds (applies to "Free" and "Request" mode
(no. 20 and 21 are added)
45
Value
Factory
range
setting
0 or 1
1
0 or 1
1
0 ... 59 sec.
45
0 or 1
0
0 ... 59 sec.
45
0 ... 2
2
0 ... 99 min.
2
0 ... 59 sec.
30