3.
The required clearance below the edge is shown in Figures
4.
In order to prevent a fall with a swinging movement, the working area and the lateral movement from the
centre line must be limited to max. 1.50m on both sides. In other cases, no single anchor points must be
used, but e.g. type C / class C anchor devices (only if approved for shared use) or type D / class D devices
according to EN 795.
5.
For use of the fall arrester on a type C / class C anchor device according to EN 795
with a horizontally mobile guide, the excursion of the anchor device must also be considered when
determining the required clearance underneath the person using the device. The information provided in the
instructions for use and the safety information of the anchor devices must be observed in this context.
6.
In case of a fall over an edge, there is a danger of injury during the process of arresting the fall due to the
falling person hitting parts of the building or structure.
7.
Special measures for rescue must be defined and trained for cases of falls over an edge.
8.
Fall arresters labelled with Figure
edges (e.g. retractable fasteners made of Dyneema or stainless steel cables).
9.
For the correct distance from the device to the edge in case of horizontal use see the list at the beginning of
these instructions for use (
15
Fall over edges at right angle
Safe distance
(minimum)
are unsuitable for the stress sustained during a fall over unprotected
14
).
18
3.00m
+ 1.00m
4.00m
+
+
.
15
16
17
16
Fall over edges with lateral offset
Safe distance
(minimum)
15
GB
13
14
17
18
3.00m
+ 1.00m
4.00m