Testing the spray functions
For the following test steps, weight must be
applied to the WC seat to simulate a user.
The LED on the lateral control panel lights
up blue during this.
kg
1
Test the anal shower function.
Result
The device performs nozzle cleaning.
The spray arm extends.
The anal shower begins with both nozzle
openings active.
After completing the shower cycle, the
spray arm retracts.
The device performs nozzle cleaning.
42
After a complete shower cycle, the device
will require around two minutes to bring the
storage water heater back to shower water
temperature. During this time, hot water will
only be available from the rear spray
nozzle.
2
Test shower water temperature.
Result
The shower water is noticeably heated over
the entire shower cycle.
3
Test adjustability of spray intensity.
Result
During a shower cycle, the spray intensity
can be altered.