B: Advanced Wiring - Honeywell TrueEASE HE100 Guide D'installation Professionnelle

Masquer les pouces Voir aussi pour TrueEASE HE100:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

B: Advanced Wiring

Wiring Configuration: Advanced Models (HE150/HE250/HE300)
Wiring HumidiPRO to TrueEASE Advanced Humidifier with Fan Interlock.
HVAC
R C
W
Y
NOTE: SEE TrueEASE INSTALL GUIDE FOR DETAILED WIRING INFORMATION.
Wiring to force the HVAC system fan on whenever humidity is needed (on demand).
G (THERMOSTAT)
R
G (FURNACE)
1
ONLY NEEDED IF SYSTEM'S THERMOSTAT DOES NOT ISOLATE Y FROM G. IF NEEDED, BREAK THE
THERMOSTAT G TO SYSTEM G CONNECTION AND ROUTE THROUGH HUMIDIFIER AS SHOWN.
2
HE150/HE250 USES A 15 VA TRANSFORMER WIRED INTO 24V IN.
HE100/HE200 USES A 10 VA TRANSFORMER WIRED INTO 24V IN
HE300 USES A LINE CORD PLUG.
Humidifier 69-2413EF—09
HumidiPRO
C
R
U
U
G
S
OUTDOOR
S
SENSOR
THERMOSTAT
G "FAN"
HE150/HE250/HE300
1
HumidiPRO
C
R
U
U
S
OUTDOOR
S
SENSOR
24VAC
CONSTANT
POWER IN
NOT REQUIRED
ON HE300
DIP SWITCH SETTING
RESET POWER AFTER
ANY DIP SWITCH CHANGES
2
POWER IN
M34577
M34834
27

Publicité