Operation using liquid gas is permitted only in well ventilated rooms -
3
which have a capacity (length x width x height) of at least 20m
and have a
window (which can be opened) or a door to the outside - or out of doors.
Outdoor use includes tents (awnings) which are well ventilated throughout unit
operation and flat garden terraces.
There are no restrictions on electrical operation.
Site of operation must be protected from rain and other water sources.
3. Storage of gas cylinders
Liquid gas cylinders should never be stored in unventilated areas or below
ground (funnel-shaped holes). Avoid direct sunlight. The gas cylinder should not
be exposed to temperatures in excess of 50°C.
4. Installation
To be installed horizontally on a smooth, firm or any other appropriate surface.
If necessary, adjust/align using a spirit level or a water-filled vessel.
There should be a distance of at least 10cm between the back of the unit and
any other object (wall).
Avoid placing unit in direct sunlight and next to other sources of heat.
Ventilating ducts of the refrigerator should be kept clear of all obstructions to
ensure a good air circulation.
This will result in a good, energy-saving cooling system.
5. Cleaning
Before initial use and after defrosting or before prolonged periods of disuse,
clean the unit containers and door with luke-warm water and, if necessary,
washing-up liquid. Warning: do not inadvertently press or force the opened door
past its stop-point (this could cause the hinges to break). Never use scouring or
corrosive agents to clean the unit. Wipe cleaned surfaces dry with a soft cloth.
6. AC operation
Check that the supply voltage and line voltage data correspond to the type-plate
in the unit.
(The following instructions refer in the main to coolers manufactured for the
United Kingdom).
The mains lead of your refrigerator is fitted with a non-rewirable moulded-on 13
amp plug containing a 3 amp fuse. It is a regular earthed plug for connection to
a regular earthed socket.
Due to the difference in the plugs used, an adapter will be necessary for other
countries.
If the fuse requires replacing at any time, the fuse cover/carrier should be
4