Maintenance

Turn engine off and key out. Release all pressure from the
system before attempting to install, service, relocate or
perform any maintenance.
In order to maintain efficient operation of the compressor system, check
the air filter and oil level before each use. The ASME safety valve should also
be checked daily (see Figures 1 and 9). Pull ring on safety valve and allow the ring to
snap back to normal position. This valve automatically releases air if the tank pressure
exceeds the preset maximum. If air leaks after the ring has been released, or the valve is
stuck and cannot be actuated by the ring, the ASME safety valve must be replaced.
Do not tamper with the ASME safety valve.
TANK
Never attempt to repair or modify a tank! Welding, drilling or
any other modifi cation will weaken the tank resulting in
damage from rupture or explosion. Always replace worn, cracked or damaged
tanks.
Drain liquid from tank daily.
The tank should be carefully inspected at a minimum of once a year. Look for cracks
forming near the welds. If a crack is detected, remove pressure from tank immediately
and replace.
COMPRESSOR LUBRICATION
See Installation. Add oil as required. The oil and oil filter should be changed every three
months or after every 500 hours of operation; whichever comes first.
If the compressor is run under humid conditions for short periods of time, the
humidity will condense in the crankcase and cause the oil to look creamy. Oil
contaminated by condensed water will not provide adequate lubrication and must be
changed immediately. Using contaminated oil will damage bearings, pistons, cylinders
and rings and is not covered under warranty. To avoid water condensation in the oil,
periodically run the compressor with tank pressure near 150 psi by opening the drain
cock or an air valve connected to the tank or hose. Run the pump for an hour at a time
at least once a week or more often if the condensation reoccurs.
IMPORTANT: Change oil after first 50 hours of operation.
IMPORTANT: The gasoline engine requires more frequent oil changes. Read engine
maintenance instructions for other periodic service requirements not covered here.

AIR FILTER

Never run the compressor pump without an intake air filter or with a clogged intake
air filter. The air filter element should be checked monthly (see Figure 10). Operating
compressor with a dirty filter can cause high oil consumption and increase oil
contamination in the discharge air. If the air filter is dirty it must be replaced.
INTERCOOLER
Intercooler fi ns are sharp, always wear gloves and use care when you
clean or work near the intercooler.
Weekly, check the intercooler to be sure all fittings are secure and tight. Clean all dirt,
dust and other accumulations from the intercooler fins.
Series CE7003TD
Figure 9 - ASME Safety Valve
Figure 10 - Air Filter
www.campbellhausfeld.com
11

Publicité

Table des Matières
loading

Table des Matières