Oxygen supplied from this device is for supplemental use and is not intended to be life
supporting or life sustaining. This device is not intended for use by patients who would
suffer immediate, permanent, or serious health consequences as a result of an
interruption in the oxygen supply.
NEVER smoke in an area where oxygen is being administered.
NEVER use near any type of flame or flammable/explosive substances, vapors or
atmosphere.
DO NOT use oils, greases, lubricants or any combustible materials on or near this
product. Wash hands properly prior to usage.
DO NOT touch liquid oxygen or parts that have been in contact with liquid oxygen. Liquid
oxygen
oxygen, or parts of the equipment that have been carrying liquid oxygen, can freeze skin
and body tissue.
TO AVOID INCREASED RISK OF FIRE
Keep this equipment away from electrical appliances.
Portable units at least five feet from electrical appliances that may cause heat or
sparks.
Keep oxygen equipment away from open flames. Use and store reservoir and
Portable at least five feet away from equipment such as furnaces, water heaters,
and stoves that may contain open flames.
Keep equipment in a well-ventilated area at all times. These devices periodically
release small amounts of oxygen gas that must be ventilated to prevent buildup.
DO NOT store liquid oxygen equipment in a closet, car trunk, or other confined area.
DO NOT place blankets, draperies, or other fabrics over equipment.
High concentrations of oxygen can cause rapid burning of other substances.
ALWAYS confirm prescribed dose before administering to patient and monitor on a
frequent basis.
DO NOT carry the Portable device under your clothing. These devices normally vent
oxygen. Wearing a Portable device under clothing may saturate fabrics with oxygen and
cause them to burn rapidly if exposed to sparks or flame. It may take several hours for
oxygen levels in fabric to return to normal.
ALWAYS keep tubing or oxygen supply line away from path of walking to avoid potential
trip or fall.
DO NOT use if dirt or contaminants are present on or around fill connectors on the
Portable device or reservoir.
NO OXYGEN is delivered when the pulse Selector is at the "0" Setting.
NO OXYGEN is delivered in between settings.
WARNING
is
extremely
cold
(-297°f/-183°c).
4
When touched, liquid
Use and store reservoir and