In Canada
1. Local codes.
2. CSA B149.1 Natural Gas and Propane Installation Code.
3. CSA C22.1 Canadian Electrical Code.
The above are available from the Canadian Standard Association, 5060 Spectrum Way, Suite 100,
Mississauga, Ontario, Canada L4W 5N6.
Casters (Optional)
Optional casters may be obtained. Appliance will require four (4) swivel casters, two (2) of which must
be braking casters.
Appliances Mounted on Casters
Appliances mounted on casters must use a flexible connector
(not supplied by Vulcan) that complies with the Standard for
Connectors for Movable Gas Appliances, ANSI Z21.69 •
CSA 6.16 and a quick-disconnect device that complies with
the Standard for Quick-Disconnect Devices for Use With
Gas Fuel, ANSI-Z21.41 • CSA 6.9. In addition, adequate
means must be provided to limit movement of the appliance
without depending on the connector and the quick-
disconnect device or its associated piping to limit appliance
movement. Attach the restraining device at the rear of the
appliance as shown in Fig. 1.
If disconnection of the restraint is necessary, turn off the
gas supply before disconnection. Reconnect this restraint
prior to turning the gas supply on and returning the aplliance
to its installation position.
Note: If the appliance is installed on casters and is moved for any reason, it is recommended that the
appliance be releveled front to back and side to side to achieve desired cooking results. If the casters
supplied are not leveling type casters, then the flooring must be adjusted or the appliance may need
to be moved to a level location of operation.
Battery Installation (GHCB Only)
Since January 5, 1998, Vulcan-Hart appliances have
changed from using Stockham gas unions to Ward (Fig. 2).
If you are installing a new battery range to an existing field
appliance, the union on the existing field appliance must be
checked against the union being used on the new range.
The union manufacturer's name around the face surface of
the union nut must match. If the new range has been
shipped using a Ward union and the old appliance has
something different—i.e., Stockham—it must be replaced
with a Ward union. Failure to replace this union could result
in a gas leak.
Extra Ward unions must be ordered through an Authorized
Vulcan Parts Depot.
– 5 –