Ergomotion Serta Motion Perfect Manuel Du Propriétaire page 5

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

safety precautions and usage statements
designed and manufactured to perform and function within designated quality
control parameters . Bases are subject to meticulous and rigorous inspections
during the quality control process to ensure bases will operate within these
standards during normal operating use . Normal operating use is defined as the
following: Adjustable foundation is to be operated with a mattress and load .
Testing procedures require lifetime cycle tests with up to 120kg distributed load .
The angle (designated "a" in figure 1) between the back section and the flat
All Ergomotion adjustable foundations, depending on make and model, are designed and manufactured to perform and
function within designated quality control parameters. Bases are subject to meticulous and rigorous inspections during
section for various configurations of the mattress support platform shall be ± 3°,
the quality control process to ensure bases will operate within these standards during normal operating use.
Normal operating use is defined as the following:
which translates to a tolerance of up to 1 ½" .
-Adjustable foundation is to be operated with a mattress and load. Testing procedures require lifetime cycle
The angle (designated "B" in figure 1) between the flat section and foot section
tests with up to 120kg distributed load.
for various configurations
of the mattress support
platform shall be ± 3°, which
translates to a tolerance of
up to ¾" .
Any adjustable foundation
deemed to be within these
allocated tolerances is
considered to have met
the manufacturer's quality
control standards .
The angle (designated "α" in figure 1) between the back section and the flat section for various configurations of the
mattress support platform shall be ± 3°, which translates to a tolerance of up to 1 ½".
THAT "NEW PRODUCT" SMELL:
The angle (designated "β" in figure 1) between the flat section and foot section for various configurations of the mattress
support platform shall be ± 3°, which translates to a tolerance of up to ¾".
Some people notice a slight odor to their new adjustable base—this can come
When operating a "paired" split base setup there may be a time latency up to 1.5 seconds between each bases articulation.
from our material manufacturing process . This smell is normal and usually
Any adjustable foundation deemed to be within these allocated tolerances is considered to have met the manufacturer's
disappears before the product reaches you . Sometimes, however, this smell may
quality control standards.
Blake Pettit
still be noticeable . It usually disappears after a few weeks, providing adequate
Quality Assurance Manager
ventilation of the product and the environment .
Ph 805-979-3875
Fx 805-979-9399
www.ergomotion.com
BREAK IN PERIOD:
You can speed up the break-in period by simply spending time in the adjustable
Ergomotion Inc.
|
ph 1-888-550-3746
bed through activities such as reading, watching TV or playing with the kids or
Adjustable
Bed Tolerance
(β°)
|
fx 805-979-9399
|
www.ergomotion.com
grandkids . The extra movement will help the adjustable base respond to weight
and temperature changes . Some of the materials in our adjustable bases such
as the woods, metals and plastics used in the platform, frame and components
are sensitive to moisture content and temperature and may make sounds in
colder environments .
PAIRED OPERATION:
When operating a "paired" split base setup there may be a time latency up to 1 .5
seconds between each bases articulation .
WEAR AND TEAR:
Wear and tear is damage that naturally and inevitably occurs as a result of
(α°)
normal use or aging .
FABRIC CARE:
To prolong the life of your fabric, protect from direct sunlight whenever possible .
For spot cleaning, wipe area with a light damp sponge or vacuum with a soft
brush attachment to remove particles . Keep at a minimum of 30cm (12 inches)
away from direct heat sources . For a deeper cleaning, blot liquid spills with a
clean dry cloth . Wipe with a clean cloth dampened with warm water . Do not wet
excessively . A soft bristle brush may be used to remove ingrained soil . Avoid
scratching by gentle brushing . Wipe with a clean cloth dampened with warm
water to remove residues . Dry in shade away from direct heat . If persistent marks
remain visible after cleaning, seek professional advice .
PRODUCT RATINGS:
The lift motors are not designed to operate continuously for more than
[2] minutes in an [18] minute time period or approximately 10% duty cycle .
Attempting to circumvent or exceed this rating will shorten the life expectancy of
the product and may void the warranty . The massage motors are not designed
to operate continuously for more than 30 minutes at a time . Please allow the
massaging system to rest for 30 minutes after automatic massage shut off before
3

Publicité

Table des Matières
loading

Table des Matières