Assembly
(Continued)
3. Find connection diagram on back
side of the cover or on motor
nameplate and reconnect to
desired voltage as indicated on
diagram .
If you do not
WARNING
!
understand this
wiring diagram you must find a
qualified electrician that does
understand wiring diagrams.
4. Change plug to match voltage and
current requirements.
When converting
WARNING
!
to an alternate
voltage, be sure the green ground wire
of the cord connects to the ground pin
of the plug and to the metal body of
the pressure switch.
Operation
START-UP
This compressor
NOTICE
pump must be
filled with oil before startup. See
lubrication section.
Do not attach air
CAUTION
!
tools to open end
of the hose until start-up is completed
and the unit checks OK.
1. Remove the dipstick breather and fill
pump to the proper oil level. See
Lubrication Section.
2. Open tank drain valve.
3. Turn pressure switch lever or knob
to OFF position and plug in power
cord.
4. Turn pressure switch lever or knob
to AUTO position and run unit for
30 minutes to break in the pump
parts (See Figure 9).
Lever - Off
Knob
Auto/Off
Lever - Auto
Figure 9
5. Turn regulator knob fully
counterclockwise. Compressor will
build to maximum preset pressure
and shut off.
6. Turn regulator knob clockwise to
cause air to bleed off. Compressor
will restart at preset pressure.
7. Turn pressure switch lever or knob
to OFF position and unplug
powercord. Slowly turn regulator
knob clockwise to allow all air
pressure to be released. Do not
proceed to the next step until the
tank pressure reaches zero (0).
8. Attach hose, then add chuck or
other tool to open end of hose.
Plug in powercord. Turn pressure
switch lever to AUTO position.
When full pressure is reached turn
regulator knob clockwise until
desired outlet pressure is achieved.
9. After use, turn pressure switch lever
or knob to the OFF position.
10. If compressor is not used for a long
time period, bleed air from line and
use drain valve to drain water from
the tank. Then, follow the
maintenance schedule.
NOTE: Electric models are equipped
with a pressure switch that
automatically turns the motor OFF
when the tank pressure reaches a
preset level. After air is used from the
tank and drops to a preset low level,
the pressure switch automatically turns
the motor back on.
Maintenance
WARNING
!
Disconnect, tag and lock
out power source, then
release all pressure from
the system before
attempting to install,
service, relocate or perform any
maintenance.
All repairs should be performed by an
authorized service representative.
FOR EFFICIENT OPERATION:
Perform the following test to verify
free operation of the safety valve
weekly and follow maintenance
schedule below.
1. Pull ring on safety valve and allow
the ring to snap back to normal
position (See Figure 10). This valve
automatically releases air if the tank
pressure exceeds the preset
maximum.
Figure 10
5
Portable Air Compressors
MOISTURE IN COMPRESSED AIR
Moisture in compressed air will form
into droplets as it comes from an air
compressor pump. When humidity is
high or when a compressor is in
continuous use for an extended
period of time, this moisture will
collect in the tank. When using a
paint spray or sandblast gun, this
water will be carried from the tank
through the hose, and out of the gun
as droplets mixed with the spray
material.
Important: This condensation will
cause water spots in a paint job,
especially when spraying other than
water based paints. If sandblasting, it
will cause the sand to cake and clog
the gun, rendering it ineffective.
A filter or air dryer in the air line,
located as near to the gun as possible,
will help eliminate moisture.
A large amount of
CAUTION
!
fast moving air will
be release if the safety valve is
actuated with air pressure in the tank.
Do not attempt to
NOTICE
tamper with this
valve. This valve should be checked
occasionally. If air leaks after the ring
has been released, or the valve is stuck
and cannot be actuated by the ring, the
safety valve must be replaced.
2. With motor OFF and unplugged,
clean debris from motor, flywheel,
tank, air lines and pump cooling
fins.
DRIVE BELT
Belts will stretch in normal use. Properly
adjusted, a 5-pound pressure applied to
the belt between the motor pulley and
the pump will deflect the belt about
1/2" (See Figure 11).
1/2" Deflection
Figure 11
TO ADJUST DRIVE BELT:
1. Remove belt guard.
www.chpower.com

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Vt470000kbVt470200kbTc100000kbVs serieVt serie

Table des Matières