Trouble Shooting - Artidor AR-024 Manuel D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Mechanical alignment: The detection area is oval shaped. Install the unit in such a manner
that the markings on the housing are positioned in the longitudinal direction of the area to be
monitored. Do not install sensors near heat sources like air-conditioning units, lights or
E
radiators.
9.

Trouble shooting

The functional indicators in the case of the Artidor AR-024 (red and green LED's) have
several functions.
Red and green LED indicating self-checking mode (over a period of 60 seconds following
mains'-supply lock-on)
Flashing at intervals of 1 second
EEPROM / memory empty
Flashing rapidly
EEPROM / memory contains information
Red LED as an indicator of status
Flashing irregularly
Movements are detected within the area of coverage
Flashing regularly
Sensor identifies bright, light off (dependent upon operating mode)
Not illuminated
Sensor identifies dark, light on (dependent upon operating mode)
Flashing extremely rapidly
Too bright / Too dark / Undefined
Red LED as an acknowledgement of receipt for commands from the remote control
Illuminated for 1 seconds
Signal validly received
Illuminated for 0.25 seconds
Not-accepted command, sensor blocked
Flashing extremely rapidly
Not-accepted command, occurs, for example, when an attempt is made to set a twilight-
value that is too high or too low
Red LED as an acknowledgement of receipt for commands from the remote control
Installation manual AR-024 explosion-safe occupancy sensor
10 / 44
04-2022

Publicité

Table des Matières
loading

Table des Matières