Measurement Reset; Troubleshooting - Lofrans GALAXY 503 Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

www.lofrans.com
6 USE
(ON) key to activate controls and to switch on the display lighting. The display lighting switches off 60 seconds
Press the
after the last command given (adjustable default time – see "BkLight Time").
Press key
(UP) to control the anchor ascending
(DOWN) to cast anchor
Press key
When any key is released (UP or DOWN) the corresponding action is stopped.

6.1 Measurement reset

To reset the measurement count simultaneously press the
Measurement reset may also be performed in the Measurement menu by selecting "Yes" in the Reset Measure row.

7 TROUBLESHOOTING

FAULT
V=11.6 Vdc
V= 7.9 Vdc
www.busse-yachtshop.de | info@busse-yachtshop.de
Measure
O f f
R e s e t M e a s u r e
U n i t s
E x i t
CAUSE
Though UP or DOWN keys
are pressed, the instrument
doesn't receive any signal from
the magnetic sensor for more
than 5 seconds.
The instrument's power
supply voltage is lower than10Vdc.
V=11.6 Vdc
V=11.6 Vdc
(ON) and the
(UP) keys for at least three seconds.
N o
F e e t
CORRECTIVE ACTION
Check the sensor electric connections.
Check if sensor operates properly.
If not, replace it.
Check the position of sensor and magnet on
gipsy and their distance (3 mm).
Check the operation of electric
installation or anchor windlass.
Verify the battery charge or
operation of the electricssystem.
UK
11

Publicité

Table des Matières
loading

Table des Matières