Télécharger Imprimer la page

Interface Protocol; Connector Layout - Dostmann Electronic P700 Mode D'emploi

Publicité

Les langues disponibles

Les langues disponibles

Accuracy
Pt100
±0.1 °C from -100 °C...+200 °C
otherwise 0.1%
Thermocouple
gem. DIN (-200...1760°C)
R, S
±1.0 °C +0.1%
K, J, L, N, T
±0.2 °C from 0 °C...+200 °C
±0.5 °C to 1000 °C
±1.0°C remaining range
Humidity
±1.5%rH
Flow
1% of end value
Resistance
-
Memory
appr. 6,000 measurements
Resolution
0.1°C, 0.1% and 0.1 m/s
Ex-mark
-
Battery life
appr. 20 hours
Connectors
DIN 8-pole
Allowable operating temp. 0 °C ... +40 °C
Display
2-line LCD
Housing
plastic
Dimensions
200 x 93 x 44 mm (LxWxH)
Weight
350 g
Power supply
9 V battery

5. Interface protocol

P700
Measuring value 1 + 2
recognize autom.
alternatively
----------------------------------------------------------------------------------------------------------
Enabling the keyboard
----------------------------------------------------------------------------------------------------------
Read version number of firmware
alternatively
----------------------------------------------------------------------------------------------------------
Read memory (only LOG-instruments)
alternatively
----------------------------------------------------------------------------------------------------------
Device serial number
----------------------------------------------------------------------------------------------------------
Interface parameter:
Baud rate
2400 baud
Data bit
8
Stop bit
2
Parity
None
Attention: By sending the command FC (hex) you will get the complete data, the
instrument lock auto-matically the keyboard. To release the keyboard you have
to send the command 0 (hex).
The datas would be sent in the following format.
Data Type = String
The length of the string depends on the instrument (a two-channel or one-chan-
nel instrument).
For PC communication with the P700 series via the USB interface,
it
is
necessary
to
use
The required driver can be found on the optional "DE-Graph" software for P700-
series (order code 5090-0081). It is also possible to download the driver from the
Internet at: www.ftdichip.com.
Depending which PC operating system Used, there are different driver versions
to select.
38
FC (hex)
ü (ASCII)
6E (hex)
n (ASCII)
6C (hex)
I(ASCII)
S (ASCII)
a
driver
(VCP
Virtual
Com

6. Connector layout

Connector layout Pt100 4-wire
Measuring channel 1 /2
Pt100 4-Wire
Connector layout thermocouple
Measuring channel 1 /2
Pt100 2-Wire
In the plug
International colours of thermocouples
Thermocouple
Typ R
0 (hex)
Pt13Rh-Pt
Typ S
Pt10Rh-Pt
Typ J
Fe-CuNi
Typ T
Cu-CuNi
Typ K
NiCr-Ni
Typ N
NiCrSi-NiSi
Typ L
Fe-CuNi
Connector layout of a probe for flow Mini Air6
(series P750/P755/770)
Measuring channel 1 /2
Port).
NiCr-Ni thermocouple
-
DIN 43 722
DIN 43 710
orange
white
+ orange – white
+ red - white
orange
white
+ orange – white
+ red - white
black
+ black - white
brown
+ brown - white
green
... green
+ green - white
+ red - green
rosa
+ pink - white
brown
+ red - blue
yellow
white
Mini Air6 Impeller
Soldering
Side
Soldering
Side
+
ANSI MC 96.1
green
+ black - red
grün
+ black - red
black
+ white - red
blue
+ blue - red
yellow
+ yellow - red
Soldering
Side
black
39

Publicité

Chapitres

loading