the floor at a downward angle. Take care, however, not to
immerse the ends of the tubes in any standing water that
may be present.
Ceilings and Cabinets
The larger lumber sizes and structural cavities in ceilings
will require more air airflow to dry properly.
Moisture under and behind cabinets may be difficult to de-
tect, but it is safest to assume that moisture is present if
water has flowed through these assemblies. Make sure to
provide as much airflow as possible. If you cannot properly
access all interior spaces, the cabinets may need to be re-
moved.
NOTICE: Do not use the DriForce to extract liquid water or
debris of any kind. This may damage the unit and void the
warranty.
Diagram shows two inline ADS lines (left), and two double-ADS
lines running from a T-fitting. It also shows tubing layouts for
one or two injectors into each wall cavity.
DriForce Blower Setup
The DriForce Blower is equipped with a blower outlet, a
vacuum inlet, a power switch and a power cord. Plug in unit
to an appropriate grounded 115V outlet rated for 15 amps.
Attach vacuum hoses to the vacuum inlet and/or blower
outlet.
Set the DriForce blower out of high traffic areas to minimize
a trip-and-fall hazard from the blower and the ADS.
NOTE: The muffler/filter supplied with the DriForce should
only be installed when using the DriForce in the Air Injec-
tion (Blower) mode, described under Phase 2 below. Do
not use the muffler-filter when using with the DriForce in
the air extraction mode (Phase 1). The filter is not intended
to be used on the inlet (vacuum) side of the DriForce.
Switch power on and off with the toggle switch, found in the
base of the unit.
07-00274K F211, F211-AK, F211-BU
Air Drying System (ADS) Setup
Manifold configuration
Next, determine the number of manifolds needed for the
job. The following setup will deliver 25 to 30 air exchanges
per hour in each cavity, which is effective for most situa-
tions. Use a formula of one manifold (each manifold has 12
injectors) for each 14 feet of interior 2 × 4 framed wall. For
2 × 6 exterior framed walls, common walls in apartments
and condos, double-sheeted fire walls, and dense or water-
resistant covered walls, use a formula of one manifold (12
injectors) for each 7 feet of wall.
After determining the number and length of hose assem-
blies and manifolds, set up the ADS system. Pre-assem-
bling the manifolds, tubing and injectors will save consider-
able time.
Supply tube configuration
Two 200 ft. (60 m) lengths of
are provided. This tubing can be cut to length with a
tubing
pair of sturdy scissors or a utility knife. We recommend the
cutting following tubing lengths to create a setup suitable
for most standard wall-drying jobs:
1. Set up THREE manifolds with the following lengths
of tubing:
Manifold
Tubing
no.
quantity
1
4
2
4
3
4
2. Set up the remaining FIVE manifolds with the follow-
ing lengths of tubing:
Manifold
Tubing
no.
quantity
4
2
5
2
6
2
7
2
8
2
9
2
To install the tubing, slide the one end of the tubing over
the manifold outlet nipple and insert an injector in the other
end.
Tightly seal off the last manifold on each run of ADS with
an end-cap plug. Now place the injectors into the holes you
have drilled or punched in the wall, cabinet or other assem-
bly.
3
of ⅜ in. (0.375 mm) ID air supply
Tubing
Tubing locations
length
on manifold outlets
4 ft.
Outlets 1, 2, 11
and 12
1.2 m
3½ ft.
Outlets 3, 4, 9 and 10
1 m
1 ft.
Outlets 5, 6, 7 and 8
30 cm
Tubing
Tubing locations
Length
on manifold outlets
7½ ft.
Outlets 1 and 12
2.3 m
6½ ft.
Outlets 2 and 11
2.0 m
5½ ft.
Outlets 3 and 10
1.7 m
4½ ft.
Outlets 4 and 9
1.4 m
2½ ft.
Outlets 5 and 8
0.8 m
1 ft.
Outlets 6 and 7
30 cm