Code
Parameter
Additional amplifier Default setting: 2
07
0 = disabled
1 = low
9 = loud
In case the additional 15 V power supply is available, you
may activate the additional amplifier, hence voice-controlled
two-way-communication and set the desired volume via this
configuration step code. In case the additional power supply is
not available or blacks out, Behnke Series 10 Intercom stations
will automatically return to their standard full-duplex operations
mode.
Operations modes Relay: Default setting: 4
08
0 = disabled
1 = to be activated via the telephone
4 = to be activated via the telephone & disconnecting after
activation
7 = activated during outgoing calls
8 = activated during incoming calls
9 = activated during both incoming and outgoing calls
10 = activated at the beginning of an outgoing call
11 = activated at the beginning of an incoming call
12 = activated at the beginning of both outgoing and incoming
calls
16 = activated during a direct call via button 1
17 = activated at the beginning of a direct dial from button 1
18 = manually activated
When using mode 18, the first activation code (configuration
step code 10) is used to turn off the relay while the second
activation code (configuration step code 11) is used to turn on
the relay.
Relay activation interval Default setting: 3
09
1 = 1 second
2 = 2 seconds
30 = 30 seconds
Use this configuration step to adjust the relay activation interval
for operations modes 1 to 4. It will also apply to the relay activa-
tion interval for operations modes 16 and 17 at the beginning of
the connection.
Relay activation codes: Specification: cf. text
10
Activation code = 1st activation code
11
Activation code = 2nd Activation code
Activation codes consist of ciphers only and each activation
code may be up to 4 characters long. The default setting for
activation code 1 is 0. There is no default setting for activation
code 2.