Refrigerant Piping Work - Haier 3U19FS1ERA Manuel D'installation

Masquer les pouces Voir aussi pour 3U19FS1ERA:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Limitations on the installation
Indoor Unit
Level
difference:
15m max.
Level
difference:
7.5m max.
If the outdoor unit is positioned higher than the indoor units.

Refrigerant piping work

1. Installing outdoor unit
1) When installing the outdoor unit, refer to "Precautions for Selecting the Location" and the "Indoor/Outdoor Unit Installation Drawings".
2)If drain work is necessary, follow the procedures below.
2. Drain work
1) Use drain plug for drainage.
2) If the drain port is covered by a mounting base or floor surface, place additional foot bases of at least 30mm in height under the
outdoor unit's feet.
3) In cold areas, do not use a drain hose with the outdoor unit.(Otherwise, drain water may freeze, impairing heating performance.)
3U19FS1ERA
Drain elbow
Level
Outdoor Unit
difference:
15m max.
4U25HS1ERA
4U30HS1ERA
5U34HS1ERA
Hose
8
Level
difference:
7.5m max.
Indoor Unit
If the outdoor unit is positioned higher than the indoor units.
(If lower than one or more indoor units.)
Drain elbow
Outdoor Unit
Hose

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

4u25hs1era4u30hs1era5u34hs1era

Table des Matières