Télécharger Imprimer la page

Rear Side Of Housing; Safety Notes; Applications And Accessories - Monacor Security DA-8000 Notice D'installation

Masquer les pouces Voir aussi pour Security DA-8000:

Publicité

Les langues disponibles

Les langues disponibles

10 PCB with the electronics
11 Anti-tamper contact of the alarm control system
12 Black cable lug for connection to the negative pole
of a 12 V rechargeable battery
13 Red cable lug for connection to the positive pole of
a 12 V rechargeable battery
14 Fuse holder for the fuse of the rechargeable bat-
tery; to replace the fuse (slow-blow 2 A), unscrew
the holder
15 Holder for the mains fuse (slow-blow 125 mA)
Only replace a blown fuse by one of the same type!
16 Connection terminal for the neutral conductor of the
230 V mains supply
17 Connection terminal for the earthed conductor of
the 230 V mains supply (only serves for holding an
earthed conductor; need not be connected)
18 Connection terminal for the phase of the 230 V
mains supply
19 Space to accommodate a 12 V rechargeable bat-
tery;
A rechargeable battery is required for the emer-
gency power supply in case of a mains failure and
for the power supply of an alarm unit in case of
alarm (connection see items 12 and 13)
1.2 Rear side of housing (fig. 2)
20 Speaker cabinet to be removed for mounting the
speaker separately and not in the housing of the
alarm control system
21 Housing holes for fixing the alarm control system
22 Mounting place for the speaker if it is not to be
accommodated in the separate cabinet (20)
23 Caps to be removed, serve for covering the fixing
screws of the keypad controllers
24 Caps to be removed, serve for covering the fixing
screws of the speaker cabinet (20)
25 Cable inlet for the connection cables
26 Mains transformer

2 Safety Notes

The units (alarm control system and keypad controller)
correspond to all required directives of the EU and are
therefore marked with
WARNING The alarm control system is supplied
with hazardous mains voltage (230 V~).
Therefore, the connection to the power
supply must only be made by expert
personnel!
cause an electric shock hazard.
It is essential to observe the following items:
The alarm control system and the keypad controllers
are suitable for indoor use only. Protect the units
against dripping water and splash water, high air
humidity, and extreme temperatures (admissible
ambient temperature range 0 – 50 °C).
.
Inexpert
handling
Do not set the alarm control system into operation,
or immediately disconnect it from the 230 V mains if
1. there is visible damage to the alarm control
system,
2. a defect might have occurred after a drop or simi-
lar accident,
3. malfunctions occur.
The units must in any case be repaired by skilled
personnel.
For cleaning only use a dry, soft cloth, by no means
chemicals or water.
No guarantee claims for the units and no liability for
any resulting personal damage or material damage
will be accepted if the units are used for other pur-
poses than originally intended, if they are not cor-
rectly connected, operated, or not repaired in an
expert way.
If the units are to be put out of operation
definitively, take them to a local recycling
plant for a disposal which is not harmful to
the environment.
Do not put defective rechargeable batte-
ries into the household rubbish but take
them to a special waste disposal (e. g. col-
lective container at your electrical supply
shop).

3 Applications and Accessories

This microprocessor-controlled alarm control system
with 8 alarm zones serves for protecting buildings,
building parts, or area zones. For this purpose alarm
sensors and signal devices are additionally required
which have to be connected to the alarm control
system, e. g.:
infrared motion detector CORAL-1MVDS*
reed contacts for doors and windows VDS-34SFF/WS*
glass break detector SHOCKGARD-2*
junction box DB-264/WS*
alarm unit SAG-12A*
telephone dialling unit DL-200*
key switch with pulsed contact (momentary push-
button) NSA-80*
alarm pushbutton APS-1*
* examples from the MONACOR product range
The supplied keypad controller which is equipped with
a 2-line alphanumerical display allows programming of
the individual alarm zones (loops) for the required fea-
tures and operation of the alarm control system. For
the operation from different locations three additional
keypad controllers (DA-8000RC from MONACOR)
may
may be connected. The cable length between keypad
controller and alarm control system must not exceed
200 m as a maximum.
For the emergency power supply in case of a mains
failure and for the power supply of an alarm unit in case
of alarm a 12 V rechargeable battery with a minimum
capacity of 2 Ah must be inserted (e. g. NPA-12/7 from
MONACOR).
GB
23

Publicité

Dépannage

loading

Ce manuel est également adapté pour:

04.3060