4. Changing the battery
If you change the battery, please proceed as follows:
Picture 1:
Loosen the battery cover
5. Technical Data:
Flow rate measurement range:
Max. permissible working pressure:
Measurement
accuracy:
Permissible
temperature range:
Viscosity of the pumped fluid:
Size
(measurement housing without accessories):
Weight
(measurement housing without accessories):
Pumped media:
Partial total display (resettable):
Overall total display (not resettable):
Power supply:
Battery life:
6. Safety Instructions:
Non-compliance with the safety instructions can result in danger both to persons and to the
environment and the equipment. Non-compliance with the safety instructions can lead to the
loss of any claims for damages. The operator of the equipment must ensure that the
contents of the Operating Instructions, particularly the Safety Instructions are known to the
operating personal.
Comply with the permissible pressures for the meter.
-
Do not use the meter in EX-protected areas.
-
The meter is calibrated at the factory (preset). Before use however check the right
-
setting with your system.
Do not point the output gun at people or animals! Danger of injury!!
When using accessories not supplied by MATO, there is sometimes the danger of an accident. No
-
liability can be accepted for accidents or damage caused by components from other sources
Defective parts must be replaced with genuine spares without delay.
-
Modification or alteration to the equipment is only permitted after discussion with the manufacturer.
-
The operational safety of the equipment is only guaranteed if used as directed.
-
Maintenance, inspection and repairs must only be carried out by qualified specialist personnel,
-
who have acquainted themselves with the subject by studying the operating instructions.
7. Maintenance and care:
Fitting an in-line filter is recommended. If the display is faint change the batteries in good time.
Protect the meter from the effects of heat.
8. Warranty:
If the operating instructions are followed and the equipment used in accordance with the directions, we
accept liability within the bounds of the statutory warranty obligations (see our Delivery Conditions).
When making warranty claims always attach the invoice from your dealer, giving the date of purchase.
8
Picture 2:
Take out the battery
1 – 35 l/min.
100 bar
+/- 0.5%
-10°C to +50°C max.
8 – 5000 mPa.s
Ø100 * 75 mm high
0.70 kg
Diesel, fuel oil, hydraulic oils
engine and transmission oils
from 0.00 to 9999,99 (6 characters)
from 0 to 99.999 (5 characters)
1 x 3V Lithium RC 123A (Ø16,5x35)
around 5 years depending on use
Picture 3:
Insert the new battery and press
the reset button to check the
function of the register
Picture 4:
Insert the battery cover,
then screw the battery
cover tight
(mineral and glycol based),
(other media on request)