6.0 PLENum ANd vENTING INSTALLATION/
CLEArANCE TO COmBuSTIBLE mATErIALS
ALL pLENUM DUCTINg AND vENTINg INSTALLATION MUST CONFORM WITH CAN/CSA B365-01,
CSA B139-09, AND NFpA 211. ALWAYS CHECk LOCAL BUILDINg AND FIRE CODES , AND AUTHORI-
ALL pLENUM, DUCTINg AND vENTINg MUST BE INSTALLED BY A qUALIFIED/LICENSED INSTALL-
DO NOT USE MAkESHIFT COMpROMISES DURINg INSTALLATION. DO NOT BLOCk OR RESTRICT
AIR. DO NOT IMpEDE AIR MOvEMENT IN zONES MARkED "CLEARANCE TO COMBUSTIBLES".
MINIMUM CLEARANCE TO COMBUSTIBLE DIMENSIONS MUST BE IMpLEMENTED.
6.1

FLuE / CHImNEy FOr HmF150/200 IN CONFIGurATIONS

stand alone wood furnace
combination wood/oil furnace
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERvINg ANOTHER AppLIANCE!!
THE WOOD FURNACE SECTION CAN OpERATE USINg A MINIMUM 6" (152 mm) Ø FLUE pIpE, BUT
WE RECOMMEND THAT THE FLUE SIzE BE SET AT A MINIMUM OF 7" (178 mm) Ø WHERE THE FUR-
NACE IS TO BE SET Up AS (OR IN CONSIDERATION TO A FUTURE RETRO FIT TO A WOOD/OIL OR
USE CHIMNEY CERTIFIED TO 2100°F (1149°C) FOR WOOD BURNINg AppLIANCES, LISTED AS
UL103HT(USA), ULCS629(CANADA) MINIMUM 6" (152 mm) DIAMETER LISTED RESIDENTIAL CHIM-
CHIMNEY DRAFT gREATER THAN -0.06" W.C. (-15 pa) MAY CAUSE AN UNCONTROLLABLE FIRE
6.1.1
Controlling draft
• use of inclined manual dampers are forbidden.
• barometric dampers can be installed to maintain normal operating draft between 0.04" and 0.06" W.C
(10 Pa and 15 Pa).
6.2

vENTING CONFIGurATION FOr wOOd/OIL COmBINATION FurNACE

vENTINg CONFIgURATION FOR BRINgINg SEpARATE WOOD AND OIL FURNACE FLUES INTO A COMMON vENT
1
2
3
4
5
LEFT HAND RA CONFIgURATION
TIES HAvINg jURISDICTION.
WOOD/OIL/ELECTRIC COMBINATION.
NEY. SEE AND FOLLOW CHIMNEY MANUFACTURES INSTRUCTIONS.
AND DAMAgE THE FURNACE.
legend
(ITEMS 1 THROUGH 11 BY INSTALLER)
6
1.
vent/chimney in accordance with CAn/
CSA-b365-01, CSA b139-09, nfPA211,
7
construction and installation by qualified licensed
installer
8
2.
7" (178 mm) T
3.
6" to 7" (152 mm to 178 mm) increaser
9
4.
6" (152 mm) T
10
5.
6" (152 mm) end cap for clean out
6.
5" to 7" (127 mm to 178 mm) increaser
7.
90° 5" (127 mm) elbow
8.
barometric damper
9.
45° 5" (127 mm) elbow (change angle to suit
incline)
10. WArninG: oil flue to be mounted on same side
11
of furnace as blower box, to respect clearance to
12
combustible dimensions.
11. 90° 5" (127 mm) elbow (offset in two directions)
12. Heat shield
ER.
combination wood/electric furnace
combination wood/electric/oil furnace
6
7
8
9
10
RIgHT HAND RA CONFIgURATION
W415-1013 / A / 06.05.12
37
1
2
3
4
5
11
12