10A
11A
THe PreSeT vAlueS on THe fAn limiT ConTrol muST noT be CHAnGed from THe fACTory
Any AdJuSTmenT To THiS ConTrol Will AffeCT THe oPerATinG effiCienCy of THe
once the set point limits have been confirmed, carefully manipulate the wiring inside the oil limit connec-
tion box so that installation of the connection box cover does not disturb or impede the mechanical set
point tabs and the rotary dial.
STEp #17
Sealing the oil flue and mounting lower heat shield:
Slide the flue fibre gasket over on the flue.
Slide the flue plate over the oil furnace flue pipe.
Secure the 5" (127 mm) flue plate to the rear panel using hex head screws (8 pcs.).
W415-1013 / A / 06.05.12
oil limiT &
mounTinG
brACkeT
bloWer module
HArneSS
LEFT HAND RA CONFIgURATION
13
14b
furnACe And Will void THe WArrAnTy CoverAGe.
oil
oil
furnACe
furnACe
flue
flue
RIgHT HAND RA CONFIgURATION
FIgURE B
CAUTION
SeTTinG.
oil limiT &
mounTinG
brACkeT
oil limiT
HArneSS
bloWer module
HArneSS
HiGH limiT
SeT PoinT
250°f (121°C)
fAn on/off
SeT PoinT 100°f (38°C)