Operating Temperature - WIKA 632.51 Mode D'emploi

Manomètres
Masquer les pouces Voir aussi pour 632.51:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3. Technical data and intended use

Operating Temperature

Ambient: -0 ... +60 °C
Attention: Footnote 1) under table 1 must be absolutely taken into account!
GB
Medium: see table 1
Attention! With gaseous substances the temperature may increase as a result
of the compression temperature. In such cases the pressure change rate has to
be slowed down resp. the permissible medium temperature has to be reduced.
Table 1: Permissible medium temperature (only mechanical part)
Ignition temperature of
the ambient atmosphere
(temperature class)
>
85 °C (T 6)
> 100 °C (T 5)
> 135 °C (T 4)
> 00 °C (T 3)
> 300 °C (T )
> 450 °C (T 1)
1) The permissible uppper ambient temperature for the electrical components is determined by
the electrical connection values and the ignition temperature of the ambient gases, vapours and
dusts. Therefore the maximum permissible ambient temperatures specified in the EC-type exami-
nation certificates for slot-type sensors and SN sensors must be observed as well. The lower of
these two values is to be considered the maximum permissible ambient temperature!
Materials (wetted parts)
Pressure connection with pressure chamber:
Pressure element (capsule element):
Sealing ring between socket and capsule element: PTFE
6
WIKA Operating instructions pressure gauges Model 63.51 with 831 per ATEX
Permissible maximum medium temperature
(in the pressure system)
+70 °C
+80 °C
+80 °C
+80 °C
+80 °C
+80 °C
Stainless steel
Stainless steel

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

904.31904.32904.28904.29904.33904.30

Table des Matières