Publicité

Liens rapides

Installer: Leave this manual with the appliance. Consumer: Retain this manual for future reference.
Operating instructiOns and Owner's Manual
Heatstar High-intensity infrared Heaters
HS4040 HS9100S
HS8060 HS9120
4000 & 8000 Models
warning:
if the information in this manual is not followed exactly, a fire or explosion
may result causing property damage, personal injury or loss of life.
— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance.
— WHAT To Do IF YoU SMell GAS
Shut off gas supply
Do not try to light appliance
Do not touch an electrical switch; do not use any phone in your building
Immediately call your gas supplier from a neighbor's phone.
Follow the gas supplier's instructions
If you cannot reach your gas supplier, call the fire department
— Installation and service must be performed by a qualified installer, service agency or the gas
supplier.
This is an unvented gas-fired heater. It uses air (oxygen) from the area in which it is used. Adequate
combustion and ventilation air must be provided. Refer to page 4.
read instructiOns careFullY: Read and follow all
instructions. Place instructions in a safe place for future
reference. Do not allow anyone who has not read these
instructions to assemble, light, adjust or operate the heater.
ENERCO GROUP INC., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 • 216-916-3000
9000 Models
18650 Rev. A 06/08

Publicité

Table des Matières
loading

Sommaire des Matières pour HeatStar HS4040

  • Page 1 Installer: Leave this manual with the appliance. Consumer: Retain this manual for future reference. Operating instructiOns and Owner’s Manual Heatstar High-intensity infrared Heaters read instructiOns careFullY: Read and follow all HS4040 HS9100S instructions. Place instructions in a safe place for future reference.
  • Page 2: Table Des Matières

    carbon Monoxide poisoning: warning: Improper installation, adjustment, Early signs of carbon monoxide poisoning resemble alteration, service or maintenance can cause property the flu, with headaches, dizziness, or nausea. If you damage, injury or death. Read the installation, opera- have these signs, the heater may not be working tion, and maintenance instructions thoroughly before properly.
  • Page 3: General Information

    1. general inFOrMatiOn edition, or Figure 1; the larger dimension of ANSI/NFPA No. 409 or Figure 1 is to be used. In Canada refer to Your heater comes fully assembled and is tested at CCA B149-1-M91 and B149.2. the factory for proper gas and input as stated on the name plate.
  • Page 4: Electrical

    a separate regulator must be installed ahead of the b.Where natural (gravity) ventilation is provided for heater. Refer to Figure 2 for maximum allowable pres- exhaust, the openings must be distributed above the sure for stated model and gas. heaters (preferably at the peak of the roof) and the areas of openings shall not be less than 300 square See heater rating plate for minimum gas supply pres- inches for every 100,000 BTU input.
  • Page 5: Connection Diagram For Flame Rod Current For Flame Rectification Systems

    cOnnectiOn diagraM FOr FlaMe rOd current FOr FlaMe rectiFicatiOn sYsteMs (dsp-5, a5) Microammeter Control Flame Terminal For Flame Flame Rod loadwire Flame Rod Assy. Figure 3 – Using a microammeter to prove adequate grounding area. Means OF prOVing adeQuate grOunding area nOte: The proper flame-rod-to-ground-area ratio cannot 1.
  • Page 6 cOMBined lOad: 1.5 aMp. PIloT BURNeR SPARK eleCTRoDe / FlAMe SeNSoR sp745 MAIN BURNeR loGIC BoX PV/MV 24 VolT THeRMoSTAT NoT THeRMoSTAT PV/MV BY HeAT STAR oPTIoNAl GAS VAlVe 120 VAC 24 VAC TRANSFORMER (SHIPPED LOOSE) Vr8204 A5 CoNNeCTIoN DIAGRAM ReF.
  • Page 7: Replacement Parts

    replacement parts list For Heaters 4000 series Models / less control Item Stock Description Req’d. 00435 A Reflector Assembly 02523 A Burner Assembly 03397 P Venturi 05437 Orifice – Br. N.G. 4040 05443 Orifice – Br. N.G. 4030 05449 Orifice – Br. L.P. 4040 05452 Orifice –...
  • Page 8 replacement parts list For Heaters 9000 series Models / less control Item Stock No. Description Req’d. 00444 A Reflector Assembly 02694 Burner Assembly 03421 P Venturi 05428 Orifice – Br. N.G. 9140 05429 Orifice – Br. N.G. 9120 05430 Orifice – Br. N.G. 9100 05443 Orifice –...
  • Page 9 replacement parts list For Heaters 9100s series Models / less control Item No. Stock No. Description Req’d. 00443 A Reflector Assembly 02508 A Burner Assembly 03421 P Venturi 05431 Orifice – Br. N.G. 9100S 05432 Orifice – Br. N.G. 9090 05437 Orifice –...
  • Page 10 FOr Heat star series 4000, 8000 replaceMent parts list FOr cOntrOl sYsteM suFFiX ndsp-5 ITeM SToCK DeSCRIPTIoN REQ’D 00028 IGNITION CONTROL #SP715A 00037 GAS VAlVe DSP-5/VR8204A2001/ 00228 CoNTRol ASSY. NDSP-5 05573 oRIFICe PIloT NG. 08353 TRANSFoRMeR 40VA 09374 PRoBe T/C 1 5/32” loNG 09375 PRoBe leAD 4000, 8000, 9000 HTRS.
  • Page 11 FOr Heat star series 4000, 8000 replaceMent parts list FOr cOntrOl sYsteM suFFiX la5 ITeM SToCK DeSCRIPTIoN REQ’D GAS VAlVe A5/VR8204A2092/11” 00036 CoNTRol loGIC /A5/ 00039 #SP745NL36005 00329 CoNTRol ASSY. lA5 05577 oRIFICe PIloT – lP 08353 TRANSFoRMeR 40VA 11407 PIloT BURNeR ASSY.
  • Page 12 FOr Heat star series 9000, 9000s replaceMent parts list FOr cOntrOl sYsteM suFFiX npp, lpp ITeM SToCK DeSCRIPTIoN REQ’D COMB. GAS VALVE (PP) NG. 00024 1/2x1/2 NPT COMB. GAS VALVE (PP) LP. 1/2x1/2 00025 05384 oRIFICe PIloT lP 05383 oRIFICe PIloT NG 09360 THeRMoCoUPle PP HoNeYWell 10367...
  • Page 13 Figure 4 clearances tO cOMBustiBles CeIlING See CHAIN KIT #17374 oR THReAD- eD RoD BACK SIDe F114581 HANGING BRACKeT KIT BeloW HOriZOntal MOunt WAll FlooR See INSTAllATIoN INSTRUCTIoNS FoR DeTAIleD CleARANCeS INFoRMATIoN Figure 5 MOunting tYpical wall MOunt ANGle IRoN ReCoMMeND USING HeATeR HANGING BRACKeT F114581...
  • Page 14: Shut-Off Valve

    Figure 6 tYpical lOw pressure standard installatiOn oN THReADeD PIPeS USe A PIPe CoMPoUND WHICH IS ReSISTANT To THe ACTIoN oF All GASeS RIGID oR FleXIBle GAS MUST Be ReSISTANT To PRoPANe lINe To HeATeR PIPe NIPPle ½ PSI MAX. HeATeR SHUT-oFF VAlVe DRIP leG...
  • Page 15 tHis page intentiOnallY leFt Blank enerco Group, Inc. | Gas-Fired Infra-Red Space Heaters Operating Instructions and Owner’s Manual...
  • Page 16: Parts Ordering Information

    ARe oNlY AVAIlABle DIReCT FRoM THe FACToRY AND MUST Be INSTAlleD BY A QUAlIFIeD SeRVICe AGeNCY. PARTS ORDERING INFORMATION: purcHasing: Accessories may be purchased at any Mr. Heater/HeatStar local dealer or direct from the factory FOr inFOrMatiOn regarding serVice Please call Toll-Free 800-251-0001 • www.enerco-mrheater.com Our office hours are 8:30 AM –...

Ce manuel est également adapté pour:

Hs9100sHs8060Hs9120

Table des Matières